Panasonic S-36PU1E5A Service Manual page 181

Table of Contents

Advertisement

Single -Type
1-1. Unit Specifi cations
PEY1
3. Wall Mounted Type S-71PK1E5A / U-71PEY1E5
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION TOTAL kWh *4
O
EER/EER CLASS
TOTAL(W/W)*5/("A"~"G")
O
Pdsign
L
SEER
(W/W)
Erp
I
Annual consumption
*6
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W)*5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
*6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
I/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
COOL
m
3
/min (ft
O/D AIR
FLOW
3
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-71PK1E5A
-
ø, Hz
1ø 50Hz
V
220
230
kW
7.1
7.1
24200
24200
A
0.59
0.58
W
57
57
-
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
47/44/40
64/59/54
dB-A
kW
7.1
7.1
24200
24200
A
0.59
0.58
W
57
57
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
47/44/40
64/59/54
dB-A
-
-
0.59/57
0.58/57
-
-
-
47
L/h(Pt/h)
4.2
Pa
-
3
/min)
18/14.5/11.5 (636/512/406)
3
/min)
18/14.5/11.5 (636/512/406)
3
/min)
3
/min)
300 (11-1/32)
1065 (41-15/16)
230 (9-1/32)
310
1140
380
14.5 (32)
18 (40)
15 (16)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
U-71PEY1E5
-
ISO5151 / EN14511 / EN14825 / EN12102
1ø 50Hz
240
220
230
7.1
24200
0.52
11.7
11.3
57
2.390k
2.390k
2.450k
2.450k
1225
1225
-
2.90
2.90 / C
-
-
7.1
-
-
5.1
-
-
487
-
-
A
-
93
92
-
-
50/-
70/-
7.1
24200
0.52
9.00
8.70
57
1.840k
1.840k
1.900k
1.900k
-
3.74
3.74 / A
-
-
6.0
-
-
-6
-
-
3.9
-
-
2154
-
-
A
-
93
92
-
-
52/-
70/-
-
0.52/57
18/3.680k
18/3.800k
-
11.7/2.4k
11.3/2.4k
-
90
(8.8)
-
39
39
R410A
1.70k
569 (22-13/32)
790 (31-7/64)
285 (11-7/32)
648
921
386
42 (93)
46 (101)
4 (5)
-10°C ~ 43°C
-15°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164.0)
(49.2/98.4)
40
(0.430)
20
(65.6)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-171
240
Min
Max
2.0
7.7
6800
26300
10.9
-
-
2.390k
-
-
2.450k
325
3.000k
1225
-
-
2.90
6.15
2.57
-
-
-
-
91
-
-
1.8
8.1
6100
27600
8.40
-
-
1.840k
-
-
1.900k
275
2.550k
3.74
6.55
3.18
-
-
-
-
-
91
-
-
18/3.930k
10.9/2.4k
(1377)
(1377)
(60.0)
/
/
/
/
/
/
/
/
/
~
~
1

Hide quick links:

Advertisement

Table of Contents
loading