Panasonic S-36PU1E5A Service Manual page 131

Table of Contents

Advertisement

Simultaneous (Triple) -Type
1-1. Unit Specifi cations
PE1
5. Ducted Type S-50PN1E5A×3 / U-140PE1E8A
INDOOR
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION TOTAL kWh *4
O
EER/EER CLASS
TOTAL(W/W)*5/("A"~"G")
O
Pdsign
L
Erp
SEER
(W/W)
I
Annual consumption
*6
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W)*5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
*6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W) 0.74×3/165×3 0.76×3/180×3 0.78×3/190×3 11.0/6.800k
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
COOL
m
3
/min (ft
I/D AIR
FLOW
3
HEAT
m
/min (ft
3
COOL
m
/min (ft
O/D AIR
FLOW
HEAT
m
3
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-50PN1E5A×3
ø, Hz
1ø 50Hz
V
220
230
kW
14.0
14.0
47800
47800
A
0.54×3
0.55×3
W
115×3
120×3
-
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
41/39/35
58/56/52
dB-A
kW
16.0
16.0
54600
54600
A
0.54×3
0.55×3
W
115×3
120×3
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
41/39/35
58/56/52
dB-A
-
-
-
-
-
85×3
L/h(Pt/h)
9.0
(3.0×3)
Pa
50 (MIN10 - MAX80)
3
/min)
[16/13/11 (565/459/388)]×3
3
/min)
[16/13/11 (565/459/388)]×3
3
/min)
3
/min)
250 (9-27/32)
780 (+100) (30-23/32) (+3-15/16)
650 (25-19/32)
345
1007
777
29 (64)
34 (75)
8 (9)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
U-140PE1E8A
CZ-P3HPC2
ISO13253 / EN14511 / EN12102
3ø 50Hz
240
380
400
14.0
47800
0.56×3
6.95
6.60
125×3
4.400k
4.400k
4.745k
4.760k
-
2380
-
2.95
2.94 / C
-
-
-
-
-
-
-
-
-
-
-
-
-
96
96
54/-
71/-
16.0
54600
0.56×3
7.00
6.65
125×3
4.440k
4.440k
4.785k
4.800k
-
3.34
3.33 / C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
96
96
-
-
55/-
71/-
-
11.0/7.150k
-
7.00/3.0k
6.65/3.0k
-
90×2
(18.9)
-
135
120
R410A
3.40k
1416 (55-3/4)
940 (37-1/32)
340 (13-13/32)
1556
1055
485
98 (216)
108 (238)
1 (2)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 75
(16.4 ~ 246.1)
(49.2/98.4)
50
(0.538)
20
(65.6)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-121
415
Min
Max
3.3
15.5
11300
52900
6.35
-
-
4.400k
-
-
4.775k
1000
6.200k
-
-
-
2.93
3.30
2.50
-
-
-
-
96
-
-
4.1
18.0
14000
61400
6.45
-
-
4.440k
-
-
4.815k
1050
6.100k
3.32
3.90
2.95
-
-
-
-
-
96
-
-
11.0/7.450k
6.45/3.0k
(4767)
(4238)
(119.9)
/
/
/
/
/
/
/
/
/
~
~
1

Hide quick links: