Simultaneous (Twin) -Type
1-1. Unit Specifications
PEY1
1. 4-Way Cassette Type S-36PU1E5A×2 / U-71PEY1E5
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION TOTAL kWh *4
O
EER/EER CLASS
TOTAL(W/W)*5/("A"~"G")
O
Pdsign
L
Erp
SEER
(W/W)
I
*6
Annual consumption
N
Class
G
POWER FACTOR
dB-A (H/M/L)
NOISE INDOOR
Power Level dB
dB-A (H/L)
NOISE OUTDOOR
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W)*5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
*6
Annual consumption
N
Class
G
POWER FACTOR
dB-A (H/M/L)
NOISE INDOOR
Power Level dB
dB-A (H/L)
NOISE OUTDOOR
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
COOL
m
/min (ft
I/D AIR
3
FLOW
HEAT
m
/min (ft
3
O/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Cool (DBT)
Condition
Heat (DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
ADD GAS AMOUNT g/m (oz/ft)
N
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air flow volume in (l/s), the value in (m
*2: If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-36PU1E5A×2
CZ-KPU21×2
ø, Hz
1ø 50Hz
V
220
230
kW
7.1
7.1
24200
24200
A
0.19×2
0.19×2
W
20×2
20×2
-
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
30/28/27
47/45/44
kW
7.1
7.1
24200
24200
A
0.17×2
0.17×2
W
20×2
20×2
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
30/28/27
47/45/44
-
-
0.19×2/20×2
0.19×2/20×2
-
-
-
60×2
L/h(Pt/h)
4.2
(2.1×2)
Pa
-
3
/min)
[14/13/12 (494/459/424)]×2
3
/min)
[14/13/12 (494/459/424)]×2
3
/min)
3
/min)
256 (10-3/32)
840 (33-3/32)
840 (33-3/32)
298
929
929
23 (51)
29 (64)
11 (12)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
flared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
U-71PEY1E5
-
ISO5151 / EN14511 / EN14825 / EN12102
1ø 50Hz
240
220
230
7.1
24200
0.18×2
10.70
10.30
20×2
2.150k
2.150k
2.190k
2.190k
1094
1095
-
3.24
3.24 / A
-
-
7.1
-
-
6.3
-
-
394
-
-
A++
-
91
91
50/-
70/-
7.1
24200
0.16×2
9.10
8.70
20×2
1.840k
1.840k
1.880k
1.880k
-
3.78
3.78 / A
-
-
6.0
-
-
-6
-
-
4.0
-
-
2100
-
-
A+
-
92
92
-
-
52/-
70/-
-
0.18×2/20×2
18/3.64k
18/3.81k
-
10.7/2.19k
10.3/2.19k
-
90
(8.8)
-
39
39
R410A
1.70k
569 (22-13/32)
790 (31-7/64)
285 (11-7/32)
645
921
386
42 (93)
46 (101)
4 (5)
-10°C ~ 43°C
-15°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
flared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164)
(49.2/98.4)
40
(0.430)
20
(65.6)
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
3
1-141
240
Min
Max
2.0
7.7
6800
26300
9.80
-
-
2.150k
-
-
2.190k
325
2.800k
1096
-
-
3.24
6.15
2.75
-
-
-
-
91
-
-
1.8
8.1
6100
27600
8.30
-
-
1.840k
-
-
1.880k
275
2.510k
3.78
6.55
3.23
-
-
-
-
-
92
-
-
18/3.97k
9.8/2.19k
(1377)
(1377)
(60.0)
/
/
/
/
/
/
/
/
/
~
~