Table E–2: IMPLEMENTATION TABLE (Sheet 4 of 4)
OBJECT
OBJECT
VARIATION
DESCRIPTION
NO.
NO.
34
2
32-bit Analog Input Reporting Deadband
con't
(default – see Note 1)
3
Short floating point Analog Input Reporting
Deadband
50
0
Time and Date
1
Time and Date
(default – see Note 1)
52
2
Time Delay Fine
60
0
Class 0, 1, 2, and 3 Data
1
Class 0 Data
2
Class 1 Data
3
Class 2 Data
4
Class 3 Data
80
1
Internal Indications
---
No Object (function code only)
see Note 3
---
No Object (function code only)
---
No Object (function code only)
Note 1:
A Default variation refers to the variation responded when variation 0 is requested and/or in class 0, 1, 2, or 3 scans. Type 30 (Analog
Input) data is limited to data that is actually possible to be used in the UR, based on the product order code. For example, Signal
Source data from source numbers that cannot be used is not included. This optimizes the class 0 poll data size.
Note 2:
For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request is sent with qualifiers 17 or 28, respec-
tively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01 (for change-
event objects, qualifiers 17 or 28 are always responded.)
Note 3:
Cold restarts are implemented the same as warm restarts – the UR is not restarted, but the DNP process is restarted.
GE Multilin
REQUEST
FUNCTION
QUALIFIER
CODES (DEC)
CODES (HEX)
1
00, 01
(read)
06
07, 08
17, 28
2
00, 01
(write)
07, 08
17, 28
1
00, 01
(read)
06
07, 08
17, 28
1
00, 01
(read)
06
07, 08
17, 28
1
00, 01
(read)
2
06
(write)
07
08
17, 28
1
06
(read)
20
(enable unsol)
21
(disable unsol)
22
(assign class)
1
06
(read)
22
(assign class)
1
06
(read)
20
07, 08
(enable unsol)
21
(disable unsol)
22
(assign class)
1
06
(read)
20
07, 08
(enable unsol)
21
(disable unsol)
22
(assign class)
1
06
(read)
20
07, 08
(enable unsol)
21
(disable unsol)
22
(assign class)
2
00
(write)
(index must =7)
13
(cold restart)
14
(warm restart)
23
(delay meas.)
C60 Breaker Management Relay
E.2 DNP IMPLEMENTATION TABLE
RESPONSE
FUNCTION
CODES (DEC)
129
(start-stop)
(response)
(no range, or all)
(limited qty)
(index)
(start-stop)
(limited qty)
(index)
129
(start-stop)
(response)
(no range, or all)
(limited qty)
(index)
129
(start-stop)
(response)
(no range, or all)
(limited qty)
(index)
129
(start-stop)
(response)
(no range, or all)
(limited qty=1)
(limited qty)
(index)
129
(response)
(no range, or all)
(no range, or all)
(no range, or all)
(limited qty)
(no range, or all)
(limited qty)
(no range, or all)
(limited qty)
(start-stop)
QUALIFIER
CODES (HEX)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
07
(limited qty)
(qty = 1)
E
E-7