GE C60 Instruction Manual page 255

Multilin breaker management relay ur series
Hide thumbs Also See for C60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 27 of 29)
ADDR
REGISTER NAME
E6D4
...Repeated for module number 22
E6D8
...Repeated for module number 23
E6DC
...Repeated for module number 24
E6E0
...Repeated for module number 25
E6E4
...Repeated for module number 26
E6E8
...Repeated for module number 27
E6EC
...Repeated for module number 28
E6F0
...Repeated for module number 29
E6F4
...Repeated for module number 30
E6F8
...Repeated for module number 31
E6FC
...Repeated for module number 32
Factory Service Password Protection (Read/Write)
F000
Modbus Factory Password
Factory Service Password Protection (Read Only)
F002
Factory Service Password Status
Factory Service - Initialization (Read Only -- Written by Factory)
F008
Load Default Settings
F009
Reboot Relay
Factory Service - Calibration (Read Only -- Written by Factory)
F010
Calibration
F011
DSP Card to Calibrate
F012
Channel to Calibrate
F013
Channel Type
F014
Channel Name
Factory Service - Calibration (Read Only)
F018
A/D Counts
Factory Service - Calibration (Read Only -- Written by Factory)
F019
Offset
F01B
Gain Stage
F01C
CT Winding
Factory Service - Calibration (Read Only)
F01D
Measured Input
Factory Service - Calibration (Read Only -- Written by Factory)
F01F
Gain Parameter
Factory Service - Calibration (Read Only)
F02A
DSP Calibration Date
Factory Service - Debug Data (Read Only -- Written by Factory)
F040
Debug Data 16 (16 items)
F050
Debug Data 32 (16 items)
Transducer Calibration (Read Only -- Written by Factory)
F0A0
Transducer Calibration Function
F0A1
Transducer Card to Calibrate
F0A2
Transducer Channel to Calibrate
F0A3
Transducer Channel to Calibrate Type
F0A4
Transducer Channel to Calibrate Gain Stage
Transducer Calibration (Read Only)
F0A5
Transducer Channel to Calibrate Counts
Transducer Calibration (Read Only -- Written by Factory)
F0A6
Transducer Channel to Calibrate Offset
F0A7
Transducer Channel to Calibrate Value
F0A9
Transducer Channel to Calibrate Gain
F0AB
Transducer Calibration Date
GE Multilin
RANGE
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 1
0 to 15
0 to 7
0 to 6
---
-32767 to 32767
-32767 to 32767
0 to 1
0 to 1
0 to 300
0.8 to 1.2
0 to 4294967295
-32767 to 32767
-2147483647 to
2147483647
0 to 1
0 to 15
0 to 7
0 to 3
0 to 1
0 to 4095
-4096 to 4095
-1.1 to 366.5
0.8 to 1.2
0 to 4294967295
C60 Breaker Management Relay
B.3 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F003
---
1
F102
---
1
F126
---
1
F126
---
1
F102
---
1
F172
---
1
F001
---
1
F140
---
---
F201
---
1
F002
---
1
F002
---
1
F135
---
1
F123
---
0.0001
F060
---
0.0001
F060
---
1
F050
---
1
F002
---
1
F004
---
1
F102
---
1
F172
---
1
F001
---
1
F171
---
1
F170
---
1
F001
---
1
F002
---
0.001
F004
---
0.0001
F060
---
1
F050
DEFAULT
B
0
0 (Disabled)
0 (No)
0 (No)
0 (Disabled)
0 (F)
0
0 (Disabled)
"0"
0
0
0 (x1)
0 (1 A)
0
1
0
0
0
0 (Disabled)
0 (F)
0
0 (dcmA IN)
0 (LOW)
0
0
0
1
0
B-35