E.2 DNP IMPLEMENTATION TABLE
Table E–2: IMPLEMENTATION TABLE (Sheet 3 of 4)
OBJECT
OBJECT
VARIATION
DESCRIPTION
NO.
NO.
30
0
Analog Input (Variation 0 is used to request
default variation)
1
32-Bit Analog Input
(default – see Note 1)
2
16-Bit Analog Input
3
32-Bit Analog Input without Flag
4
16-Bit Analog Input without Flag
5
short floating point
E
32
0
Analog Change Event (Variation 0 is used
to request default variation)
1
32-Bit Analog Change Event without
Time (default – see Note 1)
2
16-Bit Analog Change Event without Time 1
3
32-Bit Analog Change Event with Time
4
16-Bit Analog Change Event with Time
5
short floating point Analog Change Event
without Time
7
short floating point Analog Change Event
with Time
34
0
Analog Input Reporting Deadband
(Variation 0 is used to request default
variation)
1
16-bit Analog Input Reporting Deadband
(default – see Note 1)
Note 1:
A Default variation refers to the variation responded when variation 0 is requested and/or in class 0, 1, 2, or 3 scans. Type 30 (Analog
Input) data is limited to data that is actually possible to be used in the UR, based on the product order code. For example, Signal
Source data from source numbers that cannot be used is not included. This optimizes the class 0 poll data size.
Note 2:
For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request is sent with qualifiers 17 or 28, respec-
tively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01 (for change-
event objects, qualifiers 17 or 28 are always responded.)
Note 3:
Cold restarts are implemented the same as warm restarts – the UR is not restarted, but the DNP process is restarted.
E-6
REQUEST
FUNCTION
QUALIFIER
CODES (DEC)
CODES (HEX)
1
00, 01
(read)
22
06
(assign class)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
07, 08
17, 28
1
06
(read)
07, 08
1
06
(read)
07, 08
06
(read)
07, 08
1
06
(read)
07, 08
1
06
(read)
07, 08
1
06
(read)
07, 08
1
06
(read)
07, 08
1
00, 01
(read)
06
07, 08
17, 28
1
00, 01
(read)
06
07, 08
17, 28
2
00, 01
(write)
07, 08
17, 28
C60 Breaker Management Relay
RESPONSE
FUNCTION
CODES (DEC)
(start-stop)
(no range, or all)
(limited qty)
(index)
129
(start-stop)
(response)
(no range, or all)
(limited qty)
(index)
129
(start-stop)
(response)
(no range, or all)
(limited qty)
(index)
129
(start-stop)
(response)
(no range, or all)
(limited qty)
(index)
129
(start-stop)
(response)
(no range, or all)
(limited qty)
(index)
129
(start-stop)
(response)
(no range, or all)
(limited qty)
(index)
(no range, or all)
(limited qty)
129
(no range, or all)
(response)
130
(limited qty)
(unsol. resp.)
129
(no range, or all)
(response)
130
(limited qty)
(unsol. resp.)
129
(no range, or all)
(response)
130
(limited qty)
(unsol. resp.)
129
(no range, or all)
(response)
130
(limited qty)
(unsol. resp.)
129
(no range, or all)
(response)
130
(limited qty)
(unsol. resp.)
129
(no range, or all)
(response)
130
(limited qty)
(unsol. resp.)
(start-stop)
(no range, or all)
(limited qty)
(index)
129
(start-stop)
(response)
(no range, or all)
(limited qty)
(index)
(start-stop)
(limited qty)
(index)
APPENDIX E
QUALIFIER
CODES (HEX)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
17, 28
(index)
17, 28
(index)
17, 28
(index)
17, 28
(index)
17, 28
(index)
17, 28
(index)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)