GE C60 Instruction Manual page 242

Multilin breaker management relay ur series
Hide thumbs Also See for C60:
Table of Contents

Advertisement

B.3 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 14 of 29)
ADDR
REGISTER NAME
58D8
...Repeated for module number 28
58E0
...Repeated for module number 29
58E8
...Repeated for module number 30
58F0
...Repeated for module number 31
58F8
...Repeated for module number 32
B
Disturbance Detector (Read/Write Grouped Setting)
5F20
DD Function
5F21
DD Non Cur Supervision
5F22
DD Control Logic
5F23
DD Logic Seal In
5F24
DD Events
Autoreclose 1P 3P (Read/Write Setting)
6890
AR Mode
6891
AR Max Num Shots
6892
AR Block BKR1
6893
AR Close Time BKR1
6894
AR BKR Man Close
6895
AR Function
6896
AR Blk Time Mnl Cls
6897
AR 1P Init
6898
AR 3P Init
6899
AR 3P TD Init
689A
AR Multi P Fault
689B
AR BKR 1 Pole Open
689C
AR BKR 3 Pole Open
689D
AR 3P Dead Time 1
689E
AR 3P Dead Time 2
689F
AR Extend Dead T1
68A0
AR Dead T1 Extension
68A1
AR Reset
68A2
AR Reset Time
68A3
AR BKR Closed
68A4
AR Block
68A5
AR Pause
68A6
AR Inc Seq Time
68A7
AR Block BKR2
68A8
AR Close Time BKR2
68A9
AR Transfer 1 to 2
68AA
AR Transfer 2 to 1
68AB
AR BKR1 Fail Option
68AC
AR BKR2 Fail Option
68AD
AR 1P Dead Time
68AE
AR BKR Sequence
68AF
AR Transfer Time
68B0
AR Event
68B1
Reserved (16 items)
Phase Undervoltage (Read/Write Grouped Setting) (2 modules)
7000
Phase UV1 Function
7001
Phase UV1 Signal Source
7002
Phase UV1 Pickup
7003
Phase UV1 Curve
7004
Phase UV1 Delay
7005
Phase UV1 Minimum Voltage
7006
Phase UV1 Block
B-22
RANGE
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 3
1 to 2
0 to 65535
0 to 655.35
0 to 65535
0 to 1
0 to 655.35
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 655.35
0 to 655.35
0 to 65535
0 to 655.35
0 to 65535
0 to 655.35
0 to 65535
0 to 65535
0 to 65535
0 to 655.35
0 to 65535
0 to 655.35
0 to 1
0 to 1
0 to 1
0 to 1
0 to 655.35
0 to 4
0 to 655.35
0 to 1
0 to 1
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
0 to 3
0 to 65535
C60 Breaker Management Relay
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F080
---
1
F001
---
1
F300
s
0.01
F001
---
1
F300
---
1
F102
s
0.01
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.01
F001
s
0.01
F001
---
1
F300
s
0.01
F001
---
1
F300
s
0.01
F001
---
1
F300
---
1
F300
---
1
F300
s
0.01
F001
---
1
F300
s
0.01
F001
---
1
F126
---
1
F126
---
1
F081
---
1
F081
s
0.01
F001
---
1
F082
s
0.01
F001
---
1
F102
---
1
F102
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
s
0.01
F001
pu
0.001
F001
---
1
F300
DEFAULT
0 (Disabled)
0
0
0
0 (Disabled)
0 (1 & 3 Pole)
2
0
10
0
0 (Disabled)
1000
0
0
0
0
0
0
50
120
0
50
0
6000
0
0
0
500
0
10
0 (No)
0 (No)
0 (Continue)
0 (Continue)
100
3 (1 - 2)
400
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (SRC 1)
1000
0 (Definite Time)
100
100
0