B.3 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 6 of 29)
ADDR
REGISTER NAME
Breaker Arcing Current Actuals (Read Only Non-Volatile) (2 modules)
2200
Breaker x Arcing Amp Phase A
2202
Breaker x Arcing Amp Phase B
2204
Breaker x Arcing Amp Phase C
2206
...Repeated for module number 2
B
Breaker Arcing Current Commands (Read/Write Command) (2 modules)
220C
Breaker x Arcing Clear Command
220D
...Repeated for module number 2
Fault Location (Read Only)
2350
Prefault Phase A Current Magnitude
2352
Prefault Phase B Current Magnitude
2354
Prefault Phase C Current Magnitude
2356
Prefault Zero Seq Current
2358
Prefault Pos Seq Current
235A
Prefault Neg Seq Current
235C
Prefault Phase A Voltage
235E
Prefault Phase B Voltage
2360
Prefault Phase C Voltage
Synchrocheck Actuals (Read Only) (2 modules)
2400
Synchrocheck X Delta Voltage
2402
Synchrocheck X Delta Frequency
2403
Synchrocheck X Delta Phase
2404
...Repeated for module number 2
Autoreclose Status (Read Only) (6 modules)
2410
Autoreclose Count
2411
...Repeated for module number 2
2412
...Repeated for module number 3
2413
...Repeated for module number 4
2414
...Repeated for module number 5
2415
...Repeated for module number 6
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Digital I/O states (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (64 items)
Expanded Remote I/O Status (Read Only)
2F00
Remote Device States, one per register (16 items)
2F80
Remote Input States, one per register (32 items)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number Of Cycles Per Record
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
Fault Report Indexing (Read Only Non-Volatile)
3020
Number Of Fault Reports
Fault Reports (Read Only Non-Volatile) (10 modules)
3030
Fault Time
3032
...Repeated for module number 2
3034
...Repeated for module number 3
B-14
RANGE
0 to 99999999
0 to 99999999
0 to 99999999
0 to 1
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
-1000000000000 to
1000000000000
0 to 655.35
0 to 359.9
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 400000000
0 to 65535
0 to 1
0 to 1
0 to 65535
0 to 4294967295
C60 Breaker Management Relay
APPENDIX B
UNITS
STEP
FORMAT
kA2-cyc
1
F060
kA2-cyc
1
F060
kA2-cyc
1
F060
---
1
F126
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
0.001
F060
V
1
F060
Hz
0.01
F001
°
0.1
F001
---
1
F001
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F155
---
1
F108
---
1
F001
---
1
F001
---
1
F050
---
1
F001
---
1
F126
---
1
F126
---
1
F001
---
1
F050
DEFAULT
0
0
0
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Offline)
0 (Off)
0
0
0
0
0 (No)
0 (No)
0
0
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents