APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 15 of 29)
ADDR
REGISTER NAME
7007
Phase UV1 Target
7008
Phase UV1 Events
7009
Phase UV Measurement Mode
700A
Reserved (6 items)
7010
...Repeated for module number 2
Breaker Failure (Read/Write Grouped Setting) (2 modules)
7200
Breaker Failure x Function
7201
Breaker Failure x Mode
7208
Breaker Failure x Source
7209
Breaker Failure x Amp Supervision
720A
Breaker Failure x Use Seal-In
720B
Breaker Failure x Three Pole Initiate
720C
Breaker Failure x Block
720D
Breaker Failure x Phase Amp Supv Pickup
720E
Breaker Failure x Neutral Amp Supv Pickup
720F
Breaker Failure x Use Timer 1
7210
Breaker Failure x Timer 1 Pickup
7211
Breaker Failure x Use Timer 2
7212
Breaker Failure x Timer 2 Pickup
7213
Breaker Failure x Use Timer 3
7214
Breaker Failure x Timer 3 Pickup
7215
Breaker Failure x Breaker Status 1 Phase A/3P
7216
Breaker Failure x Breaker Status 2 Phase A/3P
7217
Breaker Failure x Breaker Test On
7218
Breaker Failure x Phase Amp Hiset Pickup
7219
Breaker Failure x Neutral Amp Hiset Pickup
721A
Breaker Failure x Phase Amp Loset Pickup
721B
Breaker Failure x Neutral Amp Loset Pickup
721C
Breaker Failure x Loset Time
721D
Breaker Failure x Trip Dropout Delay
721E
Breaker Failure x Target
721F
Breaker Failure x Events
7220
Breaker Failure x Phase A Initiate
7221
Breaker Failure x Phase B Initiate
7222
Breaker Failure x Phase C Initiate
7223
Breaker Failure x Breaker Status 1 Phase B
7224
Breaker Failure x Breaker Status 1 Phase C
7225
Breaker Failure x Breaker Status 2 Phase B
7226
Breaker Failure x Breaker Status 2 Phase C
7227
...Repeated for module number 2
Breaker Arcing Current Settings (Read/Write Setting) (2 modules)
72C0
Breaker x Arcing Amp Function
72C1
Breaker x Arcing Amp Source
72C2
Breaker x Arcing Amp Init
72C3
Breaker x Arcing Amp Delay
72C4
Breaker x Arcing Amp Limit
72C5
Breaker x Arcing Amp Block
72C6
Breaker x Arcing Amp Target
72C7
Breaker x Arcing Amp Events
72C8
...Repeated for module number 2
DCMA Inputs (Read/Write Setting) (24 modules)
7300
DCMA Inputs x Function
7301
DCMA Inputs x ID
7307
DCMA Inputs x Reserved 1 (4 items)
GE Multilin
RANGE
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 5
0 to 1
0 to 1
0 to 65535
0 to 65535
0.001 to 30
0.001 to 30
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
0.001 to 30
0.001 to 30
0.001 to 30
0.001 to 30
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 5
0 to 65535
0 to 65.535
0 to 50000
0 to 65535
0 to 2
0 to 1
0 to 1
---
0 to 65535
C60 Breaker Management Relay
B.3 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F109
---
1
F102
---
1
F186
0 (Phase to Ground)
---
1
F001
---
1
F102
---
1
F157
---
1
F167
---
1
F126
---
1
F126
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F167
---
1
F300
s
0.001
F001
kA2-cyc
1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
---
F205
---
1
F001
DEFAULT
0 (Self-reset)
0 (Disabled)
0
B
0 (Disabled)
0 (3-Pole)
0 (SRC 1)
1 (Yes)
1 (Yes)
0
0
1050
1050
1 (Yes)
0
1 (Yes)
0
1 (Yes)
0
0
0
0
1050
1050
1050
1050
0
0
0 (Self-reset)
0 (Disabled)
0
0
0
0
0
0
0
0 (Disabled)
0 (SRC 1)
0
0
1000
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
"DCMA Ip 1 "