GE C60 Instruction Manual page 246

Multilin breaker management relay ur series
Hide thumbs Also See for C60:
Table of Contents

Advertisement

B.3 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 18 of 29)
ADDR
REGISTER NAME
9028
...Repeated for module number 3
903C
...Repeated for module number 4
9050
...Repeated for module number 5
9064
...Repeated for module number 6
9078
...Repeated for module number 7
B
908C
...Repeated for module number 8
90A0
...Repeated for module number 9
90B4
...Repeated for module number 10
90C8
...Repeated for module number 11
90DC
...Repeated for module number 12
90F0
...Repeated for module number 13
9104
...Repeated for module number 14
9118
...Repeated for module number 15
912C
...Repeated for module number 16
FlexElement Actuals (Read Only) (16 modules)
9A01
FlexElement Actual
9A03
...Repeated for module number 2
9A05
...Repeated for module number 3
9A07
...Repeated for module number 4
9A09
...Repeated for module number 5
9A0B
...Repeated for module number 6
9A0D
...Repeated for module number 7
9A0F
...Repeated for module number 8
9A11
...Repeated for module number 9
9A13
...Repeated for module number 10
9A15
...Repeated for module number 11
9A17
...Repeated for module number 12
9A19
...Repeated for module number 13
9A1B
...Repeated for module number 14
9A1D
...Repeated for module number 15
9A1F
...Repeated for module number 16
Setting Groups (Read/Write Setting)
A000
Setting Group for Modbus Comm (0 means group 1)
A001
Setting Groups Block
A002
FlexLogic Operands to Activate Grps 2 to 8 (7 items)
A009
Setting Group Function
A00A
Setting Group Events
Setting Groups (Read Only)
A00B
Current Setting Group
Digital Elements (Read/Write Setting) (16 modules)
B000
Digital Element x Function
B001
Digital Element x Name
B015
Digital Element x Input
B016
Digital Element x Pickup Delay
B018
Digital Element x Reset Delay
B01A
Digital Element x Block
B01B
Digital Element x Target
B01C
Digital Element x Events
B01D
Digital Element x Reserved (3 items)
B020
...Repeated for module number 2
B040
...Repeated for module number 3
B060
...Repeated for module number 4
B080
...Repeated for module number 5
B-26
RANGE
-2147483.647 to
2147483.647
0 to 7
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 7
0 to 1
---
0 to 65535
0 to 999999.999
0 to 999999.999
0 to 65535
0 to 2
0 to 1
---
C60 Breaker Management Relay
APPENDIX B
UNITS
STEP
FORMAT
---
0.001
F004
---
1
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F102
---
1
F001
---
1
F102
---
---
F203
---
1
F300
s
0.001
F003
s
0.001
F003
---
1
F300
---
1
F109
---
1
F102
---
---
F001
DEFAULT
0
0
0
0
0 (Disabled)
0 (Disabled)
0
0 (Disabled)
"Dig Element 1 "
0
0
0
0
0 (Self-reset)
0 (Disabled)
0
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents