GE C60 Instruction Manual page 24

Multilin breaker management relay ur series
Hide thumbs Also See for C60:
Table of Contents

Advertisement

2.1 INTRODUCTION
Table 2–4: ORDER CODES FOR REPLACEMENT MODULES
POWER SUPPLY
CPU
FACEPLATE
2
DIGITAL I/O
CT/VT DSP
L60 INTER-RELAY
COMMUNICATIONS
L90 INTER-RELAY
COMMUNICATIONS
TRANSDUCER I/O
2-4
UR - ** -
|
1H
|
125 / 250 V AC/DC
|
1L
|
24 - 48 V (DC only)
|
9A
|
RS485 + RS485 (ModBus RTU, DNP 3.0)
|
9C
|
RS485 + 10BaseF (MMS/UCA2, ModBus TCP/IP, DNP 3.0)
|
9D
|
RS485 + Redundant 10BaseF (MMS/UCA2, ModBus TCP/IP, DNP 3.0)
|
3C
|
Horizontal Faceplate with Display & Keypad
|
3F
|
Vertical Faceplate with Display & Keypad
|
6A
|
2 Form-A (Voltage w/ opt Current) & 2 Form-C Outputs, 8 Digital Inputs
|
6B
|
2 Form-A (Voltage w/ opt Current) & 4 Form-C Outputs, 4 Digital Inputs
|
6C
|
8 Form-C Outputs
|
6D
|
16 Digital Inputs
|
6E
|
4 Form-C Outputs, 8 Digital Inputs
|
6F
|
8 Fast Form-C Outputs
|
6G
|
4 Form-A (Voltage w/ opt Current) Outputs, 8 Digital Inputs
|
6H
|
6 Form-A (Voltage w/ opt Current) Outputs, 4 Digital Inputs
|
6K
|
4 Form-C & 4 Fast Form-C Outputs
|
6L
|
2 Form-A (Current w/ opt Voltage) & 2 Form-C Outputs, 8 Digital Inputs
|
6M
|
2 Form-A (Current w/ opt Voltage) & 4 Form-C Outputs, 4 Digital Inputs
|
6N
|
4 Form-A (Current w/ opt Voltage) Outputs, 8 Digital Inputs
|
6P
|
6 Form-A (Current w/ opt Voltage) Outputs, 4 Digital Inputs
|
6R
|
2 Form-A (No Monitoring) & 2 Form-C Outputs, 8 Digital Inputs
|
6S
|
2 Form-A (No Monitoring) & 4 Form-C Outputs, 4 Digital Inputs
|
6T
|
4 Form-A (No Monitoring) Outputs, 8 Digital Inputs
|
6U
|
6 Form-A (No Monitoring) Outputs, 4 Digital Inputs
|
8A
|
Standard 4CT/4VT
|
8B
|
Sensitive Ground 4CT/4VT
|
8C
|
Standard 8CT
|
8D
|
Sensitive Ground 8CT
|
8Z
|
HI-Z 4CT
|
7U
|
110/125 V, 20 mA Input/Output Channel Interface
|
7V
|
48/60 V, 20 mA Input/Output Channel Interface
|
7Y
|
125 V Input, 5V Output, 20 mA Channel Interface
|
7Z
|
5 V Input, 5V Output, 20 mA Channel Interface
|
7A
|
820 nm, multi-mode, LED, 1 Channel
|
7B
|
1300 nm, multi-mode, LED, 1 Channel
|
7C
|
1300 nm, single-mode, ELED, 1 Channel
|
7D
|
1300 nm, single-mode, LASER, 1 Channel
|
7E
|
Channel 1: G.703; Channel 2: 820 nm, multi-mode LED
|
7F
|
Channel 1: G.703; Channel 2: 1300 nm, multi-mode LED
|
7G
|
Channel 1: G.703; Channel 2: 1300 nm, single-mode ELED
|
7Q
|
Channel 1: G.703; Channel 2: 820 nm, single-mode LASER
|
7H
|
820 nm, multi-mode, LED, 2 Channels
|
7I
|
1300 nm, multi-mode, LED, 2 Channels
|
7J
|
1300 nm, single-mode, ELED, 2 Channels
|
7K
|
1300 nm, single-mode, LASER, 2 Channels
|
7L
|
Channel 1 - RS422; Channel 2 - 820 nm, multi-mode, LED
|
7M
|
Channel 1 - RS422; Channel 2 - 1300 nm, multi-mode, LED
|
7N
|
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
|
7P
|
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, LASER
|
7R
|
G.703, 1 Channel
|
7S
|
G.703, 2 Channels
|
7T
|
RS422, 1 Channel
|
7W
|
RS422, 2 Channels
|
72
|
1550 nm, single-mode, LASER, 1 Channel
|
73
|
1550 nm, single-mode, LASER, 2 Channel
|
74
|
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, LASER
|
75
|
Channel 1 - G.703, Channel 2 - 1550 nm, single -mode, LASER
|
5C
|
8 RTD Inputs
|
5E
|
4 dcmA Inputs, 4 RTD Inputs
|
5F
|
8 dcmA Inputs
C60 Breaker Management Relay
2 PRODUCT DESCRIPTION
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents