GE C60 Instruction Manual page 256

Multilin breaker management relay ur series
Hide thumbs Also See for C60:
Table of Contents

Advertisement

B.3 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 28 of 29)
ADDR
REGISTER NAME
Transducer Calibration (Read Only)
F0AD
Transducer Channel to Calibrate Units
Factory Service Software Revisions (Read Only)
F0F0
Compile Date
F0F3
Boot Version
B
F0F4
Front Panel Version
F0F5
Boot Date
Factory Service - Serial EEPROM (Read Only -- Written by Factory)
F100
Serial EEPROM Enable
F101
Serial EEPROM Slot
F102
Serial EEPROM Load Factory Defaults
F110
Serial EEPROM Module Serial Number
F120
Serial EEPROM Supplier Serial Number
F130
Serial EEPROM Sub Module Serial Number (8 items)
Factory Service CPU Diagnostics (Read Only Non-Volatile)
F200
Operating Hours
Factory Service CPU Diagnostics (Read Only)
F210
DSP Spurious Interrupt Counter
Factory Service CPU Diagnostics (Read Only -- Written by Factory)
F220
Real Time Profiling
F221
Enable Windview
F222
Factory Reload Cause
F236
Clear Diagnostics
Factory Service CPU Performance (Read Only)
F300
CPU Utilization
Factory Service CPU Performance (Read/Write)
F301
CPU Overload
Factory Service CPU Performance (Read Only)
F302
Protection Pass Time
Factory Service CPU Performance (Read/Write)
F303
Protection Pass Worst Time
Factory Service DSP Diagnostics (Read Only) (3 modules)
F380
DSP Checksum Error Counter
F382
DSP Corrupt Settings Counter
F384
DSP Out Of Sequence Error Counter
F386
DSP Flags Error Counter
F38D
DSP Error Flags
F38E
DSP Error Code
F38F
DSP Usage
F390
...Repeated for module number 2
F3A0
...Repeated for module number 3
Modbus File Transfer Area 2 (Read/Write)
FA00
Name of file to read
Modbus File Transfer Area 2 (Read Only)
FB00
Character position of current block within file
FB02
Size of currently-available data block
FB03
Block of data from requested file (122 items)
Auxiliary Overvoltage (Read/Write Grouped Setting) (3 modules)
FC30
Auxiliary OV X Function
FC31
Auxiliary OV X Signal Source
FC32
Auxiliary OV X Pickup
FC33
Auxiliary OV X Pickup Delay
FC34
Auxiliary OV X Reset Delay
FC35
Auxiliary OV X Block
B-36
RANGE
---
0 to 4294967295
0 to 655.35
0 to 655.35
0 to 4294967295
0 to 1
0 to 15
0 to 1
---
---
---
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
---
0 to 1
0 to 100
0 to 6553.5
0 to 65535
0 to 65535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65535
0 to 65535
0 to 100
---
0 to 4294967295
0 to 65535
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 65535
C60 Breaker Management Relay
APPENDIX B
UNITS
STEP
FORMAT
---
---
F206
---
1
F050
---
0.01
F001
---
0.01
F001
---
1
F050
---
1
F102
---
1
F172
---
1
F126
---
---
F203
---
---
F203
---
---
F203
---
1
F050
---
1
F003
---
1
F102
---
1
F102
---
---
F200
---
1
F126
%
0.1
F001
%
0.1
F001
us
1
F001
us
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F001
---
1
F001
---
0.1
F001
---
---
F204
---
1
F003
---
1
F001
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
DEFAULT
(none)
0
1
1
0
0 (Disabled)
0 (F)
0 (No)
(none)
(none)
(none)
0
0
0 (Disabled)
0 (Disabled)
(none)
0 (No)
0
0
0
0
0
0
0
0
0
0
0
(none)
0
0
0
0 (Disabled)
0 (SRC 1)
300
100
100
0
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents