2 PRODUCT DESCRIPTION
The relay is available as a 19-inch rack horizontal mount unit or as a reduced size (¾) vertical mount unit, and consists of
five UR module functions: Power Supply, CPU, CT/VT DSP, Digital Input/Output, and Transducer Input/Output. Each of
these modules can be supplied in a number of configurations which must be specified at the time of ordering. The informa-
tion required to completely specify the relay is provided in the following table (full details of available relay modules are con-
tained in the HARDWARE chapter).
Table 2–3: ORDER CODES
C60 - * 00 - H C * - F ** - H ** - M ** - P ** - U ** - W **
C60 - * 00 - V F * - F ** - H ** - M ** - P **
BASE UNIT
C60
|
|
CPU
A |
C |
D |
SOFTWARE
00
MOUNT /
H C |
FACEPLATE
V F |
POWER SUPPLY
CT/VT DSP
DIGITAL I/O
TRANSDUCER
I/O (MAXIMUM
OF 3 PER UNIT)
The order codes for replacement modules to be ordered separately are shown in the following table. When ordering a
replacement CPU module or Faceplate, please provide the serial number of your existing unit.
GE Multilin
| | |
|
|
|
| | |
|
|
|
| | |
|
|
|
| | |
|
|
|
| | |
|
|
|
|
|
|
|
|
|
H
|
|
|
L
|
|
|
8A
|
8A
8B
|
8B
8C
|
8C
8D
|
8D
|
XX
XX
6A
6A
6A
6B
6B
6B
6C
6C
6C
6D
6D
6D
6E
6E
6E
6F
6F
6F
6G
6G
6G
6H
6H
6H
6K
6K
6K
6L
6L
6L
6M
6M
6M
6N
6N
6N
6P
6P
6P
6R
6R
6R
6S
6S
6S
6T
6T
6T
6U
6U
6U
5C
5C
5C
5E
5E
5E
5F
5F
5F
C60 Breaker Management Relay
For Full Sized Horizontal Mount
|
|
For Reduced Size Vertical Mount
|
|
|
Base Unit
|
|
|
RS485 + RS485 (ModBus RTU, DNP)
|
|
|
RS485 + 10BaseF (
|
|
|
RS485+Redundant 10BaseF (
|
|
|
No Software Options
|
|
|
Horizontal (19" rack)
|
|
|
Vertical (3/4 size)
|
|
|
125 / 250 V AC/DC
|
|
|
24 - 48 V (DC only)
|
|
|
Standard 4CT/4VT
|
|
|
Sensitive Ground 4CT/4VT
|
|
|
Standard 8CT
|
|
|
Sensitive Ground 8CT
XX
XX
No module
2 Form-A (Voltage w/ opt Current) & 2 Form-C Outputs,
6A
6A
8 Digital Inputs
2 Form-A (Voltage w/ opt Current) & 4 Form-C Outputs,
6B
6B
4 Digital Inputs
6C
6C
8 Form-C Outputs
6D
6D
16 Digital Inputs
6E
6E
4 Form-C Outputs, 8 Digital Inputs
6F
6F
8 Fast Form-C Outputs
6G
6G
4 Form-A (Voltage w/ opt Current) Outputs, 8 Digital Inputs
6H
6H
6 Form-A (Voltage w/ opt Current) Outputs, 4 Digital Inputs
6K
6K
4 Form-C & 4 Fast Form-C Outputs
2 Form-A (Current w/ opt Voltage) & 2 Form-C Outputs,
6L
6L
8 Digital Inputs
2 Form-A (Current w/ opt Voltage) & 4 Form-C Outputs,
6M
6M
4 Digital Inputs
6N
6N
4 Form-A (Current w/ opt Voltage) Outputs, 8 Digital Inputs
6P
6P
6 Form-A (Current w/ opt Voltage) Outputs, 4 Digital Inputs
6R
6R
2 Form-A (No Monitoring) & 2 Form-C Outputs, 8 Digital Inputs
6S
6S
2 Form-A (No Monitoring) & 4 Form-C Outputs, 4 Digital Inputs
6T
6T
4 Form-A (No Monitoring) Outputs, 8 Digital Inputs
6U
6U
6 Form-A (No Monitoring) Outputs, 4 Digital Inputs
5C
5C
8 RTD Inputs
5E
5E
4 dcmA Inputs, 4 RTD Inputs
5F
5F
8 dcmA Inputs
2.1 INTRODUCTION

2.1.2 ORDERING

)
MMS/UCA2, ModBus TCP/IP, DNP
MMS/UCA2, ModBus TCP/IP, DNP
2
)
2-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents