GE C60 Instruction Manual page 239

Multilin breaker management relay ur series
Hide thumbs Also See for C60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 11 of 29)
ADDR
REGISTER NAME
429E
...Repeated for module number 16
42A0
...Repeated for module number 17
42A2
...Repeated for module number 18
42A4
...Repeated for module number 19
42A6
...Repeated for module number 20
42A8
...Repeated for module number 21
42AA
...Repeated for module number 22
42AC
...Repeated for module number 23
42AE
...Repeated for module number 24
42B0
...Repeated for module number 25
42B2
...Repeated for module number 26
42B4
...Repeated for module number 27
42B6
...Repeated for module number 28
42B8
...Repeated for module number 29
42BA
...Repeated for module number 30
42BC
...Repeated for module number 31
42BE
...Repeated for module number 32
42C0
...Repeated for module number 33
42C2
...Repeated for module number 34
42C4
...Repeated for module number 35
42C6
...Repeated for module number 36
42C8
...Repeated for module number 37
42CA
...Repeated for module number 38
42CC
...Repeated for module number 39
42CE
...Repeated for module number 40
42D0
...Repeated for module number 41
42D2
...Repeated for module number 42
42D4
...Repeated for module number 43
42D6
...Repeated for module number 44
42D8
...Repeated for module number 45
42DA
...Repeated for module number 46
42DC
...Repeated for module number 47
42DE
...Repeated for module number 48
Installation (Read/Write Setting)
43E0
Relay Programmed State
43E1
Relay Name
CT Settings (Read/Write Setting) (6 modules)
4480
Phase CT Primary
4481
Phase CT Secondary
4482
Ground CT Primary
4483
Ground CT Secondary
4484
...Repeated for module number 2
4488
...Repeated for module number 3
448C
...Repeated for module number 4
4490
...Repeated for module number 5
4494
...Repeated for module number 6
VT Settings (Read/Write Setting) (3 modules)
4500
Phase VT Connection
4501
Phase VT Secondary
4502
Phase VT Ratio
4504
Auxiliary VT Connection
4505
Auxiliary VT Secondary
4506
Auxiliary VT Ratio
4508
...Repeated for module number 2
GE Multilin
RANGE
0 to 1
---
1 to 65000
0 to 1
1 to 65000
0 to 1
0 to 1
50 to 240
1 to 24000
0 to 6
50 to 240
1 to 24000
C60 Breaker Management Relay
B.3 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F133
0 (Not Programmed)
---
---
F202
A
1
F001
---
1
F123
A
1
F001
---
1
F123
---
1
F100
V
0.1
F001
:1
1
F060
---
1
F166
V
0.1
F001
:1
1
F060
DEFAULT
B
"Relay-1"
1
0 (1 A)
1
0 (1 A)
0 (Wye)
664
1
1 (Vag)
664
1
B-19