Louver Control; Louver Position; Air Direction Adjustment - Toshiba RAS-B07G3KVSG-E Service Manual

Indoor/outdoor unit, r32 or r410a inverter
Hide thumbs Also See for RAS-B07G3KVSG-E:
Table of Contents

Advertisement

Item

8. Louver control

This function controls the air direction of the indoor unit.
1) Louver
• The position is automatically controlled according to the operation
position
mode (COOL/HEAT).
• The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
The angle of the louver is indicated as the louver closes fully is 0°.
1) Louver position in cooling operation
2) Louver position in heating operation

2) Air direction adjustment

Horizontal
blowing
Operation flow and applicable data, etc.
Cooling operation/
AUTO (COOL
Initial setting of "Cooling storage position"
Louver : Directs downward (39.5°)
Heating operation/
AUTO (HEAT)
Initial setting of "Heating storage position"
Louver : Directs downward (79.1°)
Air direction
Inclined
Blowing
blowing
downward
Inclined
Horizontal
blowing
blowing
- 41 -
Description
• The louver position can
be arbitrarily set up by
pressing [FIX] button.

Advertisement

Table of Contents
loading

Table of Contents