8. Louver control

This function controls the air direction of the indoor unit.
1) Louver
• The position is automatically controlled according to the operation
position
mode (COOL/HEAT).
• The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
The angle of the louver is indicated as the louver closes fully is 0°.
1) Louver position in cooling operation
2) Louver position in heating operation

2) Air direction adjustment

Horizontal
blowing

3) Swing

• Swing operation is perfor in range 35° with the Fixed position as
the center.
• If the swing range exceeded either upper or lower limit position,
swing operation is perfomed in range 35° from the limit.
Operation flow and applicable data, etc.
Cooling operation/
AUTO (COOL
Initial setting of "Cooling storage position"
Louver : Directs downward (40.9°)
Heating operation/
AUTO (HEAT)
Initial setting of "Heating storage position"
Louver : Directs downward (80.5°)
Air direction
Inclined
Blowing
blowing
downward
Upper Limit
Position.
o
17.5
Swing
o
17.5
o
range 35
Fixed Position
Lower Limit
before start
Position.
swing.
Inclined
Horizontal
blowing
blowing
Upper Limit
o
5
Position.
Fixed
o
30
Position
before start
swing
Swing
Lower Limit
o
range 35
Position
- 34 -
Description
• The louver position can
be arbitrarily set up by
pressing [FIX] button.
• Swing
When pressing
[SWING] button during
operation, the louver
starts swinging.