Label
PARAMETER_NAME
INST_ALERTS_ENABLE
Electronics Enable
ELECT_ENABLE
4
Sensor Enable
SENSOR_ENABLE
Environment Enable
ENVIRO_ENABLE
Travel Enable
TRAVEL_ENABLE
Proximity Enable
PROX_ENABLE
Travel History Enable
TVL_HISTORY_ENABLE
Performance Enable
PERF_ENABLE
86
Table 4-14. Transducer Block Parameter Definitions (Continued)
Index
RO /
Mode
Range
Number
RW
75
0: Drive Current
1: Drive Signal
2: Program Memory
3: Static Memory
75.1
RW
ALL
4: Processor
5: I/O Processor
6: Output Block Timeout
7: Blocks Set to Defaults
0: Travel Sensor
1: Port A Pressure
Sensor
2: Port B Pressure
75.2
RW
ALL
Sensor
3: Supply Pressure
Sensor
4: Temperature Sensor
0: Supply Pressure High
1: Supply Pressure Low
75.3
RW
ALL
2: Temperature High
3: Temperature Low
0: Travel Deviation
1: Travel High High
2: Travel Low Low
75.4
RW
ALL
3: Travel High
4: Travel Low
0: Travel Open
1: Travel Closed
2: Proximity High High
75.5
RW
ALL
3: Proximity High
4: Proximity Low
5: Proximity Low Low
0: Cycle Counter
75.6
RW
ALL
1: Travel Accumulator
0: Performance Critical
1: Performance
75.7
RW
ALL
Reduced
2: Performance
Information
−Continued−
Protect
Initial Value
Category
Enabled Bits:
0: Drive Current
1: Drive Signal
2: Program
Data Type: Bit String (4 byte)
Memory
0=disable
SETUP
3: Static Memory
1=enable
4: Processor
Electronic Alerts Enable
5: I/O Processor
7: Block Set to
Default
Enabled Bits:
0: Travel Sensor
1: Port A
Pressure Sensor
Data Type: Bit String (4 byte)
2: Port B
0=disable
SETUP
Pressure Sensor
1=enable
3: Supply
Sensor Alerts Enable
Pressure Sensor
4: Temperature
Sensor
Enabled Bits:
0: Supply
Data Type: Bit String (4 byte)
Pressure High
0=disable
2: Temperature
SETUP
1=enable
High
Environment Alerts Enable
3: Temperature
Low
Data Type: Bit String (4 byte)
Enabled Bits:
0=disable
0: Travel
SETUP
1=enable
Deviation
Travel Alerts Enable
Data Type: Bit String (4 byte)
0=disable
All bits: 0
SETUP
1=enable
Proximity Alerts Enable
Data Type: Bit String (4 byte)
0=disable
All bits: 0
SETUP
1=enable
Travel History Alerts Enable
Enabled Bits:
Data Type: Bit String (4 byte)
0: Performance
0=disable
Critical
SETUP
1=enable
1: Performance
Performance Alerts Enable
Reduced