DVC6200f Digital Valve Controller
PlantWeb Alert
(Group)
(Default Alert Category)
Drive Current
(Electronics)
(Failed)
Drive Signal
(Electronics)
(Maintenance)
Processor Impaired
(Electronics)
(Maintenance)
Output Block Timeout
(Configuration)
(Maintenance)
C
Blocks Set to Default
(Configuration)
(Maintenance)
Shutdown Alert
(Configuration)
(Maintenance)
254
Table C-2. Setting PlantWeb Alerts
Alert Condition
What the Alert is
(Default)
Detecting
The difference between the
expected Drive Current and
Drive Current
the actual Drive Current has
(Enabled)
exceeded the Drive Current
Alert Time.
If one of the following
conditions exist:
Where Zero Power Condition
is defined as closed:
SDrive Signal
<
Calibrated Travel
SDrive Signal
Drive Signal
>
Calibrated Travel
(Enabled)
Where Zero Power Condition
is defined as open:
SDrive Signal
<
Calibrated Travel
SDrive Signal
>
Calibrated Travel
Program Memory
A pending Flash or NVM
(Enabled)
failure is present.
A failure of the FRAM memory
Static Memory
where static parameters are
(Enabled)
stored.
Processor
A failure of the main
(Enabled)
Processor.
I/O Processor
A failure of the I/O Processor.
(Enabled)
If the analog or discrete output
Output Block
block has not executed for
Timeout
longer than the configured
(Disabled)
timeout.
If the resource block has
Blocks Set to Default
undergone Restart with
(Enabled)
Defaults
A user configured Self Test
N/A
Shutdown condition has taken
the instrument to OOS.
Related Parameters and
(Default)
Self Test Shutdown (No)
Shutdown Recovery (Auto)
Alert Point (50%)
Alert Time (5 sec)
10% and
3%
>
90% and
97%
<
10% and
97%
<
90% and
3%
>
Self Test Shutdown (No)
Shutdown Recovery (Auto)
Self Test Shutdown (No)
Shutdown Recovery (Auto)
Self Test Shutdown (No)
Shutdown Recovery (Auto)
Self Test Shutdown (No)
Shutdown Recovery (Auto)
Timeout Alert Point (600 s)
Self Test Shutdown (No)
Shutdown Recovery (Auto)
None
None
−Continued−
Guidelines for Setting
Use default settings
Use default setting
Use default settings
Use default settings
Use default settings
Use default settings
Enable this alert for loops where the
execution is critical. If the AO or DO
block is not scheduled, or scheduled
incorrectly, it will trigger an alert after the
Timeout Alert Point has been exceeded.
Set the Timeout Alert Point to a value
between
a. 30 seconds and
b. the maximum time before a user
should be notified. The minimum number
depends on the time it takes for a host to
download a configuration to the device.
Shutdown can be enabled if it is desired
to move the valve to the Zero Power
Condition at the same time that the alert
is generated.
Use default settings
Use default settings