AudioCodes Mediant 500 E-SBC User Manual page 257

Enterprise session border controller digital voip media gateway
Hide thumbs Also See for Mediant 500 E-SBC:
Table of Contents

Advertisement

User's Manual
To configure a SIP Interface:
1.
Open the SIP Interface Table page (Configuration tab > VoIP menu > VoIP Network
> SIP Interface Table).
2.
Click Add; the following dialog box appears:
3.
Configure a SIP Interface according to the parameters described in the table below.
4.
Click Submit, and then save ("burn") your settings to flash memory.
Parameter
Index
[SIPInterface_Index]
Interface Name
CLI: interface-name
[SIPInterface_InterfaceName
]
Network Interface
CLI: network-interface
[SIPInterface_NetworkInterf
ace]
Application Type
CLI: application-type
[SIPInterface_ApplicationTy
pe]
UDP Port
CLI: udp-port
[SIPInterface_UDPPort]
Version 6.8
Table 17-4: SIP Interface Table Parameter Descriptions
Defines an index for the new table record.
The valid value is 0 to 31.
Defines an arbitrary name to easily identify the SIP Interface.
The valid value is a string of up to 21 characters.
Assigns a Control-type IP network interface to the SIP Interface. This
string value must be identical (case-sensitive) to that configured in
the 'Interface Name' field of the Interface table (see ''Configuring IP
Network Interfaces'' on page 113).
By default, no value is defined.
Defines the application type associated with the SIP Interface.
[0] GW/IP2IP (default) = Gateway / IP-to-IP application.
[1] SAS = Stand-Alone Survivability (SAS) application.
[2] SBC = SBC application.
Defines the listening and source UDP port.
The valid range is 1 to 65534. The default is 5060.
Notes:
This port must be outside of the RTP port range.
Each SIP Interface must have a unique signaling port (i.e., no two
SIP Interfaces can share the same port - no port overlapping).
Description
257
17. Control Network
Mediant 500 E-SBC

Advertisement

Table of Contents
loading

Table of Contents