Power Supplies; Peripheral Bays - NEC NovaScale R480 E1 User Manual

Table of Contents

Advertisement

Power Supplies

The server can continue its operation without interruption even if a single power supply unit fails (power redundant
configuration).
In addition, if the AC power of each power supply unit is divided into two lines, the server can continue its operation
without power interruption even if one of the AC power line fails (AC power redundant configuration).
If the power cord is disconnected from the power supply unit immediately after it is connected, the event "power
degraded" may not be registered in the OS event log, and only the event "power recovered" is registered.
Redundant Power Configuration
Your server is configured with the 100 VAC non-redundant power supply system at the factory.
To use your server with the redundant power system (100 VAC or 200 VAC), update the Platform Information Area
(PIA) and Sensor Data Record (SDR) in the server firmware.
Contact your supplier to obtain the latest firmware.

Peripheral Bays

The server is equipped with one slot to install a backup device such as a magnetic tape drive.
Available Devices
The 5-inch device slot can contain a single-height SCSI device.
Setting the SCSI ID
When connecting the 5-inch device with the optional SCSI controller, refer to the manual that comes with the
SCSI controller.
– Setting the terminator
Set the terminator to "OFF".
2-13

Advertisement

Table of Contents
loading

Table of Contents