When the STATUS lamp lights amber
Description
On-screen
message
Recommended action
Err Pause in POST
The system is either waiting for a key entry due to a serious POST error or
the POST was terminated forcedly because a serious POST error has
occurred.
1. See "POST Error Messages" described earlier to find the error contents
2. Reboot (reset) the server.
3. Turn off the DC power of the server, and disconnect the AC power cord.
If the error persists, contact your service representative.
Hang in POST
The system hangs during POST.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
If the error persists, contact your service representative.
BIOS Recovery run
A fatal error occurred on the system BIOS ROM.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
If the error persists, contact your service representative.
Mem(xx) D(y) Unc
An uncorrectable error occurred on a DIMM in the following location.
Err
(xx): Memory board that contains the failed DIMM.
(y):
1. Reboot (reset) the server.
2. Check the installation status of the failed DIMM.
3. Replace the failed DIMMs.
If the error persists, contact your service representative.
PCI Slot(x) Unc Err
An uncorrectable error occurred on the PCI card installed in the PCI slot (x).
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
3. Check the installation status of the failed PCI card.
4. Replace the failed PCI card.
If the error persists, contact your service representative.
PCIE Unc Err(x)
An uncorrectable error occurred on the PCI Express bus.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
If the error persists, contact your service representative.
Chipset Unc Err(x)
An uncorrectable error occurred on the chipset.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
If the error persists, contact your service representative.
FBD CH(x) Unc Err
An uncorrectable error occurred on a memory board in the following
location.
(x):
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
3. Check the installation status of the failed DIMMs.
4. Replace the failed DIMMs.
If the error persists, contact your service representative.
and the actions to take regarding the displayed message.
Connect the AC power cord again, and reboot the server.
Connect the AC power cord again, and reboot the server.
Connect the AC power cord again, and reboot the server.
AB: Memory board A or B
CD: Memory board C or D
Slot number of the memory board that contains the failed DIMM.
Connect the AC power cord again, and reboot the server.
Connect the AC power cord again, and reboot the server.
Connect the AC power cord again, and reboot the server.
Memory board that contains the failed DIMM.
1: Memory board A
2: Memory board B
3: Memory board C
4: Memory board D
Connect the AC power cord again, and reboot the server.