Technical data

Nominal power
Operating temperature
Minimum operating temperature (T min.)
Maximum operating temperature (T max.)
Overpressure
Working overpressure
Permissible operating overpressure (p max.) 16 bar
Test overpressure
Capacity
Water tank
Coffee bean hopper
Twin coffee bean hopper*
Special bean hopper*
Powder container*
Twin powder container*
Large powder container*
Grounds container
External dimensions
Width
Height (incl. max. foot height)
Depth
Empty weight
Continuous sound pressure level***
Description
A monitored external waste water tank in-
stead of a waste water outlet.
SCP
Powerpack**
2,000 – 2,400 W
5,500 – 6,300 W
Steam boiler
Hot water boiler
115°C
70°C
135°C
98°C
Steam boiler
Hot water boiler
4 bar
16 bar
16 bar
24 bar
24 bar
5.2 l
600 g
2 x 600 g
1 x 1,200 g
700 g
2 x 700 g
1,400 g
40 coffee grounds cakes
SCP
Powerpack*
346 mm
346 mm
570 mm
570 mm
518 mm
598 mm
SCP
Powerpack*
25 kg
33 kg
SCP
Powerpack*
<70 dB (A)
<70 dB (A)
www.schaerer.com