Level application example

The application is a vessel that takes an average 3 hours (180 minutes) to fill and 3 weeks
to empty.
Fill rate = 0.08 m/minute [(Low Cal Pt. minus High Cal Pt.) / fastest of fill or empty time]
= (15.5 m – 1 m) / 180 min.
= 14.5 m /180 min. = 0.08 m/min.
SITRANS LR200
Quick Start Parameter
Material (1.2.)
Response Rate (1.3.)
Units (1.4.)
Operating Mode (1.5.)
Low Calibration Point (1.6.)
High Calibration Point (1.7.)
Apply? (Apply changes) (1.8.)
7ML19985JP02
SITRANS LR200 (HART) – INSTRUCTION MANUAL
1.0 m
High
Cal.
Point
14.5
Level
Setting
LIQUID
SLOW
m
LEVEL
15.5
1.0
YES
Sensor
Reference
Point
15.5 m
Low
Calibration
Point
Description
Response rate = 0.1 m/minute.
Material level referenced from Low Cal. Point.
Process empty level.
Process full level.
Save new settings.