Threaded Connection, Ptfe Rod, External Shield - Siemens Sitrans LR200 Instruction Manual

Hart
Hide thumbs Also See for Sitrans LR200:
Table of Contents

Advertisement

Threaded Connection
WARNING: For pressure applications, it will be necessary to use PTFE tape
or other appropriate thread sealing compound, and to tighten the process
connection beyond hand-tight.
Notes:
• Process temperature and pressure capabilities are dependent upon information on the
process device tag. Reference drawing listed on the tag is available on the product page
of our website at: www.siemens.com/LR200, under More Info/Installation drawings/Level
Measurement/Installation Drawings/LR200.
• Additional information on process connections is available on the Installation Drawings
page under Process Connection Diagrams.
nameplate
locking
ring
process
device
tag
stainless steel
mounting thread
stainless steel
antenna shield
(inactive length)
active antenna
SL = min. 100 mm (4"), customer-specified
L
= 374 mm (14.7") plus shield length
* 17 mm (0.67")
Page 152
SITRANS LR200 (HART) – INSTRUCTION MANUAL
PTFE Rod, external shield
,
Shield
Length
SL
187 mm
7.4"
*
sensor
reference
point
Overall
Length
L
7ML19985JP02

Advertisement

Table of Contents
loading