Raised Face Or Flat-Face Flange With Waveguide - Siemens Sitrans LR200 Instruction Manual

Hart
Hide thumbs Also See for Sitrans LR200:
Table of Contents

Advertisement

1)
Raised Face
Notes:
• For other flange dimensions and bolt hole sizing see
Raised-Face Flange Dimensions
page 161 or
• You can connect a maximum of two waveguides together.
• This option is recommended only for clean liquids on vessels without agitators or
turbulence.
• Horizontal stress on this antenna must be avoided, otherwise mechanical support may be
required.
• Process temperature and pressure capabilities are dependent upon information on the
process device tag. Reference drawing listed on the tag is available on the product page
of our website at: www.siemens.com/LR200, under More Info/Installation drawings/Level
Measurement/Installation Drawings/LR200.
• Additional information on process connections is available on the Installation Drawings
page under Process Connection Diagrams.
process device tag
sensor
reference
point
* Flange thickness: See
Flange Dimensions
Flat-Face Flange Dimensions
or
on page 161
.
1)
Per EN-1092-1.
2)
Constant thickness series.
7ML19985JP02
2)
or Flat-Face
nameplate
locking ring
diameter
80 mm (3.0")
57.2 mm
(2.250")
waveguide
Raised-Face
on page 159
SITRANS LR200 (HART) – INSTRUCTION MANUAL
Flange with Waveguide
Flat-Face Flange Dimensions
on page 159.
187 mm (7.4")
20 mm (0.8")
variable
on
*
min: 100 mm (4")
max: 3000 mm (123")
Page 155