6.3.3.3

X100 DRIVE-CLiQ interface

Table 6-18
DRIVE-CLiQ interface
Pin
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Yamaichi, Order No.: Y-ConAS-13
The maximum DRIVE-CLiQ cable length is 100 m.
6.3.3.4

X120 EP terminals / temperature sensor connection

Table 6-19
Terminal strip X120
Terminal
1
2
3
4
5
6
7
8
Max. connectable cross-section 1.5 mm
This is the only temperature channel for Order No. 6SL3040-0LA01-0AA0.
1)
For Order No. 6SL3040-0LA01-0AA1, this is the second temperature channel (T2), which
can be used as single channel dependent on the parameterization or in combination with the
first temperature channel (T1, refer to X23).
The EP terminals must be wired on the Power Module on chassis units.
2)
NOTICE
The KTY temperature sensor/the PTC must be connected with the correct polarity.
AC Drive
Manual, (GH6), 07/2007 Edition, 6SL3097-2AL00-0BP2
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
GND (0 V)
Function
Reserved, do not use
Reserved, do not use
M
+Temp
1)
-Temp
1)
Reserved, do not use
EP +24 V
2)
EP M1
2)
2
6.3 Control Unit CU310 PN (PROFINET)
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronic ground
Technical specifications
Ground
KTY or PTC input
Ground for KTY or PTC
Safe standstill input (+)
Safe standstill input (-)
Control Units