6.5.3.5

X210 EP terminals / temperature sensor connection

Table 6-43
Terminal strip X210
Terminal
1
2
3
4
Max. connectable cross-section 1.5 mm
Type: Screw terminal 1 (see Connection Methods)
NOTICE
The KTY temperature sensor/the PTC must be connected with the correct polarity.
Note
The temperature sensor connection is required for motors whose temperature value is not
transmitted by DRIVE-CLiQ.
24 V DC must be applied to terminals 3 and 4 for operation if the "Safe Standstill" function is
selected. Upon removal, pulse inhibit is activated.
AC Drive
Manual, (GH6), 07/2007 Edition, 6SL3097-2AL00-0BP2
Function
+Temp
-Temp
EP +24 V (Enable Pulses)
EP M1 (Enable Pulses)
2
6.5 CUA32 Control Unit Adapter
Technical specifications
Temperature sensor connection KTY84–1C130/PTC
Supply voltage: 24 V DC (20.4 V - 28.8 V)
Current consumption: 10 mA
Isolated input
Signal propagation times:
L → H: 100 μs
H → L: 1000 μs
Control Units