Electronics Power Supply X124; X200 - X201 Profinet - Siemens SINAMICS S120 Manual

Sinamics family modular motion control drives
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Note
A 24 V voltage supply must be connected to terminal X124 so that the digital outputs can be
used.
If a the 24 V supply is briefly interrupted, then the digital outputs are de-activated during this
time.
6.3.3.6

Electronics power supply X124

Table 6-21
Terminal block X124
Terminal
+
+
M
M
Max. cross-section that can be connected: 2.5 mm
Type: Screw terminal 2 (see Appendix A)
Note
The two "+" and "M" terminals are jumpered in the connector. This ensures the supply
voltage is looped through.
The current consumption increases by the value for the DRIVE-CLiQ node.
6.3.3.7

X200 - X201 PROFINET

Table 6-22
PROFINET interfaces X200 - X201
Pin
1
2
3
4
5
6
7
8
Connector type: RJ45plus socket
Cable type: PROFINET
AC Drive
Manual, (GH6), 07/2007 Edition, 6SL3097-2AL00-0BP2
Function
Electronics power supply
Electronics power supply
Electronic ground
Electronic ground
2
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
6.3 Control Unit CU310 PN (PROFINET)
Technical specifications
Voltage: 24 V DC (20.4 V - 28.8 V)
Current consumption: max. 0.8 A (without DRIVE-CLiQ
or digital outputs)
Max. current via jumper in connector:
20 A at 55 °C
Meaning
Transmit data +
Transmit data -
Receive data +
Receive data -
Control Units