Supplementary System Components and Encoder System Integration
7.3 Sensor Module Cabinet-Mounted SMC10
7.3.3.5

Meaning of LEDs on the Sensor Module Cabinet 10 / 20 (SMC10 / SMC20)

Table 7-11
Sensor Module Cabinet 10 / 20 (SMC10 / SMC20) – description of the LEDs
LED
Color
RDY
-
off
READY
Green
Continuous
Orange
Continuous
Red
Continuous
Green/
Flashing
0.5 Hz
red
Flashing
2 Hz
Green/
Flashing
orange
light
or
Red/
orange
Cause and rectification of faults
The following reference contains further information about the cause and rectification of
faults:
Reference: /IH1/ SINAMICS Commissioning Manual.
242
Status
Electronics power supply is missing or outside permissible
tolerance range.
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component.
Note:
LED is driven irrespective of the corresponding messages
being reconfigured.
Firmware is being downloaded.
Firmware download is complete. Wait for POWER ON
Component recognition via LED is activated (p0144)
Note:
Both options depend on the LED status when component
recognition is activated via p0144 = 1.
Description, cause
Manual, (GH6), 07/2007 Edition, 6SL3097-2AL00-0BP2
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON