Siemens SINAMICS S120 Manual page 94

Sinamics family modular motion control drives
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Power Modules
3.1 Power Modules Blocksize (PM340)
Line voltage 3-ph. 380 V to 480 V AC
PM340
6SL3210-
PM340 with integrated
6SL3210-
line filter
Rated pulse frequency
kHz
Power loss
kW
Cooling air requirement
m
Sound pressure level
dB(A)
24 V DC supply for the
A
Control Unit
Rated input current
A
1)
with line reactor
-
- without line reactor
Resistance value of the
Ohms
external braking resistor
Max. cable length to
m
braking resistor
Line supply connection
L, N
Motor connection
U2, V2, W2
DC link connection,
connection for braking
resistor DCP/R1, DCN,
R2
PE connection
Max. motor cable
m
length
2)
Degree of protection
Height
PM 340 with integrated
mm
line filter
Depth
- PM340 with Control
mm
Unit CU310
- PM340 with CUA31
Frame size
Weight, approx. without
kg
line filter/
with integrated line filter
1) The input current depends on the motor load and line impedance. The input currents apply for a load with the rated power (based on In) for a
line impedance corresponding to uk = 1%.
2) Max. motor cable length 25 m (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3
Category C2.
94
1SE23-2UA0
1SE23-2AA0
4
0.40
/s
0.038
3
< 60
1.0
33
39
> 56
15
Screw terminals
for cable cross-
sections 2.5 to
10 mm
2
Screw terminals
for cable cross-
sections 2.5 to
10 mm
2
Screw terminals
for cable cross-
sections 2.5 to
10 mm
2
at the housing
with M 5 screw
50 (shielded)
75 (unshielded)
IP20 or IPXXB
333.4 (13.12)
274.6 (10.81)
215.3 (8.47)
FSC
6.5
6.5
1SE23-8UA0
1SE24-5UA0
1SE23-8AA0
1SE24-5AA0
4
4
0.38
0.51
0.022
0.022
< 60
< 60
1.0
1.0
40
47
46
53
> 27
> 27
15
15
Stud M6,
Stud M6,
connectable
connectable
cable cross-
cable cross-
sections 10 to
sections 10 to
35 mm
35 mm
2
2
Stud M6,
Stud M6,
connectable
connectable
cable cross-
cable cross-
sections 10 to
sections 10 to
35 mm
35 mm
2
2
Stud M6,
Stud M6,
connectable
connectable
cable cross-
cable cross-
sections 10 to
sections 10 to
35 mm
35 mm
2
2
at the housing
at the housing
with M6 screw
with M6 screw
70 (shielded)
70 (shielded)
100 (unshielded)
100 (unshielded)
IP20 or IPXXB
IP20 or IPXXB
511 (20.11)
511 (20.11)
293.1 (11.53)
293.1 (11.53)
233.8 (9.20)
233.8 (9.20)
FSD
FSD
15.9
15.9
19.3
19.3
Manual, (GH6), 07/2007 Edition, 6SL3097-2AL00-0BP2
1SE26-0UA0
1SE27-5UA0
1SE26-0AA0
1SE27-5AA0
4
4
0.69
0.99
0.039
0.022
< 60
< 60
1.0
1.0
63
78
72
88
> 27
> 15
15
15
Stud M6,
Stud M6,
connectable
connectable
cable cross-
cable cross-
sections 10 to
sections 10 to
35 mm
35 mm
2
2
Stud M6,
Stud M6,
connectable
connectable
cable cross-
cable cross-
sections 10 to
sections 10 to
35 mm
35 mm
2
2
Stud M6,
Stud M6,
connectable
connectable
cable cross-
cable cross-
sections 10 to
sections 10 to
35 mm
35 mm
2
2
at the housing
at the housing
with M6 screw
with M6 screw
70 (shielded)
70 (shielded)
100 (unshielded)
100 (unshielded)
IP20 or IPXXB
IP20 or IPXXB
511 (20.11)
633 (24.92)
293.1 (11.53)
293.1 (11.53)
233.8 (9.20)
233.8 (9.20)
FSD
FSE
15.9
19.8
19.3
27.1
AC Drive

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents