# After 802.1X user usera passes authentication, execute the display connection command to display the
user connection information on GigabitEthernet 1/0/1. For more information about the display
connection command, see the chapter ―AAA configuration commands.‖
[Sysname-GigabitEthernet1/0/1] display connection interface gigabitethernet 1/0/1
Index=68
,Username=usera@my-domian
MAC=0015-e9a6-7cfe
IP=3.3.3.3
IPv6=N/A
Total 1 connection(s) matched.

dot1x max-user

Syntax
In system view:
dot1x max-user user-number [ interface interface-list ]
undo dot1x max-user [ interface interface-list ]
In Layer 2 Ethernet interface view:
dot1x max-user user-number
undo dot1x max-user
View
System view, Layer 2 Ethernet interface view
Default level
2: System level
Parameters
user-number: Specifies the maximum number of concurrent 802.1X users on a port. The value ranges from
1 to 256.
interface interface-list: Specifies an Ethernet port list, which can contain multiple Ethernet ports. The
interface-list argument is in the format of interface-list = { interface-type interface-number [ to interface-
type interface-number ] } & <1- 1 0>, where interface-type represents the port type, interface-number
represents the port number, and & <1- 1 0> means that you can provide up to 10 ports or port ranges. The
start port number must be smaller than the end number and the two ports must be of the same type.
Description
Use the dot1x max-user command to set the maximum number of concurrent 802.1X users on a port.
Use the undo dot1x max-user command to restore the default.
By default, the maximum number of concurrent 802.1X users on a port is 256.
In system view:
If you do not specify the interface-list argument, the command applies to all ports.
If you specify the interface-list argument, the command applies to the specified ports.
In Layer 2 Ethernet port view, the interface-list argument is not available and the command applies to only
the Ethernet port.