Group 5
The printer must be always be switched off and the mains plug
must be always unplugged if you plug and/or unplug any
connectors!
5.3.3 Explosion protection
The device has to be integrated in the lightning protection concept of the operator!
Further more protection measures regarding electrostatics have to be made!
5.3.4 Print head
Inflammable (Risk of fire)!
Combustible gases and liquids cause serious burns. Sources of
ignition must be kept away from the print head and the device!
Risk of injury!
Ink escapes from the head aperture. Spraying of ink into the eyes
can cause blindness. Eye protection is necessary!
The print head should be mounted to the printed product that the notch in the head
cover is placed vertical to the moving direction of the product. It can be installed
horizontal, vertical, from the top or from the bottom.
For installation from the bottom it has to be prevented that dirt can enter in the
print head. For this a head ventilation is required which can be purchased optionally.
The print head mounting should be carried out that a fast separation of the print
head from the device for cleaning purposes is possible.
JET2 neo
Transport/Start up
Page 35
Release R1.07 en