Group 5
Basic data/Recommended working conditions:
Signal
PrintGo
/PrintGo
PrintGo Gate
You will find a circuit diagram of the interface in the appendix of this
manual!
(1)
All 24V outputs designated with (1) are protected by a self-reset fuse with 700 mA.
JET2 neo
Transport/Start up
Parameter
Input level High
Input level Low
Minimum pulse duration
Input resistance
Input level High
Input level Low
Minimum pulse duration
Input resistance
Input level High
Input level Low
Minimum pulse duration
Input resistance
Value
15 up to 30V
-3,5V up to 3,5V (or high resistance)
100μS
6,8 kOhm
20 up to 28V (or high resistance)
-6V up to 9V
100μS
6,8kOhm
15 up to 30V
-3,5V up to 3,5V (or high resistance)
100μS
6,8 kOhm
Page 47
Release R1.07 en