Interface X4 (Inputs) - Leibinger JET2 neo Manual

Hide thumbs Also See for JET2 neo:
Table of Contents

Advertisement

Group 5

5.5.4 Interface X4 (Inputs)

13 inputs for special functions are available whereof the connections of 3 inputs
can be freely selected.
Plug assignment:
Basic data /Recommended working conditions:
Signal
All signals
Increment Counter/
Reset Counter
Power ON
Jobselect 0-7
Input 1-3
1)
All 24V ouputs which are designated with (1) are protected by a self-reset fuse with 700 mA.
(2)
For a change of the Jobselect inputs it has to be carried out within the duration of bounce,
that means only after termination of this period of time the new Jobselect No. is validated.
JET2 neo
Transport/Start up
Pin connection:
Pin
Designation
1
+Reset Counter
2
+Increment Counter
3
+Jobselect 0
4
+Jobselect 2
5
+Jobselect 4
6
+Jobselect 6
7
8
GND Jobselect 0-9
9
+Input 1
10
+Input 3
11
12
13
GND 24V
Parameter
Input level High
Input level Low
Input resistance
Minimum pulse width
Minimum pulse width
Maximum duration
of bounce
Minimum pulse widths Depending on assigned function
Pin
Designation
14
+24V
(1)
15
GND Reset Counter /
Increment Counter
16
+Jobselect 1
17
+Jobselect 3
18
+Jobselect 5
19
+Jobselect 7
20
21
GND Input 1-3
22
+Input 2
23
24
25
Value
15 up to 30V
-3,5V up to 3,5V (or high resistance)
6,8kOhm
250μs
2,5 s
10 ms
(2)
(see following table)
Page 49
Release R1.07 en

Hide quick links:

Advertisement

Table of Contents
loading