Mounting Procedure - Omron E3X-DRT21 Operation Manual

Fiber amplifier sensor communication units
Table of Contents

Advertisement

Mounting
5-1-1

Mounting Procedure

1,2,3...
Applicable Slave Connectors (Yes: Can be used; No: Cannot be used)
Fiber Amplifier Sensor
Communication Unit
E3X-DRT21 (DeviceNet)
E3X-SRT21 (CompoBus/S) Yes
E3X-CIF11 (RS-422)
Always use the Slave Connectors specified in the above table. Do not use
the Slave Connectors listed as not being applicable.
DeviceNet or CompoBus/S
Communication Units
Fiber Amplifier Unit
4. Connect the Fiber Amplifier Units to each other only after mounting the
Units to the DIN Track.
Use the following procedure to mount the Fiber Amplifier Sensor Communica-
tion Unit.
1. Hook the top of the Unit onto the DIN Track.
Fiber Amplifier Sensor Communication Unit
2. Push the bottom of the Unit onto the DIN Track.
Slave Connector for Fiber Amplifier Unit
Cordless
Cord with
E3X-CN02
E3X-CN12
Yes
No
No
Yes
Yes
RS-422 Communication Unit
Fiber Amplifier Unit
E3X-CN02
only
Plug in
here
DIN Track
Push in direction of
arrows.
Section 5-1
Cord with
1 wire
2 wires
E3X-CN22
No
No
No
E3X-CN12
or
Plug in
E3X-CN02
here
99