Omron E3X-DRT21 Operation Manual page 58

Fiber amplifier sensor communication units
Table of Contents

Advertisement

Setting, Monitoring, and Operating Sensors from the DeviceNet Configurator
Note Select E3X-DA6 for the E3X-DA8, E3X-DAB6, E3X-DAB8, E3X-
DAG6, and E3X-DAG8. Select E3X-DATW for the E3X-DA6TW and
E3X-DA8TW.
b) Click the Settings Button to the right of the registered Fiber Amplifier
Unit to display the following Edit Sensor Parameters Dialog Box.
Note There are no settings for E39-TM1 Terminal Block Units, so the Set-
tings Button is disabled.
c) Set the following items from the Edit Sensor Parameters Dialog Box.
(The items displayed will vary according to the Fiber Amplifier Unit
model used.)
• Threshold Level: Threshold Settings
• Function Setting Flags: Basic Settings
• Range of Time: Timer Setting
• Monitor Output Upper Limit
• Monitor Output Lower Limit
• Hysteresis: Hysteresis Width
• Custom Flags
• Special Flags
For Basic Settings (Function Setting Flags), double-click the Function
Setting Flags Field to display the following dialog box. Set the basic set-
tings, such as Eco Mode (see note below), for each Sensor.
Note "Eco Mode" is a power-saving mode and stands for "ecologically friendly"
mode.
Section 2-7