CompoWay/F Message Communications
Read Special Flags
Response Codes
Normal Completion
Error Completion
Reads the status of the following setting items. This command is possible with
E3X-DA6TW and E3X-DA8TW Sensors only. An error will occur if this com-
mand is executed for any other Sensor.
Bit
00
0 or 1
01
0 or 1
02
Always 0.
03
04
Operating Mode Flag (one-word):
0: Dark-ON
1: Light-ON
05
06
Area Setting Flag:
0: AREA OFF
1: AREA ON
07
0 or 1
08
09
Always 0.
10
Always 0.
11
Always 0.
12
Always 0.
13
Always 0.
14
Always 0.
15
Always 0.
Note Bits 00, 01, and 07 are read as 0 or 1 according to the internal status of the
Sensor.
Response code
"0000"
Response
Error name
code
"1001"
Command too long
"1002"
Command too short
"1003"
Number of elements/
data mismatch
"1101"
Area type error
"1103"
Start address out-of-
range error
"1104"
End address out-of-
range error
Contents
Name
Normal completion
The command is too long.
The command is too short.
The number of data does not match the number
of elements.
The area type is wrong.
The read start address is out of range.
The unit number of an unconnected Sensor is
specified as the read start address.
The bit position is set to other than "00".
The specified number of elements is out of
range.
Section 4-5
Description
No error has occurred.
Cause
85