Read Controller Status (Mrc = "06", Src = "01") - Omron E3X-DRT21 Operation Manual

Fiber amplifier sensor communication units
Table of Contents

Advertisement

CompoWay/F Message Communications
4-5-7

Read Controller Status (MRC = "06", SRC = "01")

Command Block
Response Block
92
This service reads the operating status and number of Sensors able to com-
municate.
The following diagram shows the command text in the CompoWay/F com-
mand block.
MRC
SRC
"06"
"01"
2 bytes
2 bytes
The following diagram shows the command text in the CompoWay/F response
block.
MRC
SRC
"06"
"01"
2 bytes
2 bytes
Operating Status
"00": Sensors communicating normally.
"01": Sensor communications error.
"02": Mobile Console is connected.
Related Information
The related information is 00 unless the operating status is "01".
The information varies according to the type of error, as follows:
Code
"00"
No response from unit number 1 onwards.
"01"
All Units up to unit number 1 are operating normally.
No response from unit number 2 onwards.
"02"
All Units up to unit number 2 are operating normally.
No response from unit number 3 onwards.
"03"
All Units up to unit number 3 are operating normally.
No response from unit number 4 onwards.
"04"
All Units up to unit number 4 are operating normally.
No response from unit number 5 onwards.
"05"
All Units up to unit number 5 are operating normally.
No response from unit number 6 onwards.
"06"
All Units up to unit number 6 are operating normally.
No response from unit number 7 onwards.
"07"
All Units up to unit number 7 are operating normally.
No response from unit number 8 onwards.
"08"
All Units up to unit number 8 are operating normally.
No response from unit number 9 onwards.
"09"
All Units up to unit number 9 are operating normally.
No response from unit number 10 onwards.
"10"
All Units up to unit number 10 are operating nor-
mally. No response from unit number 11 onwards.
"11"
All Units up to unit number 11 are operating nor-
mally. No response from unit number 12 onwards.
"12"
All Units up to unit number 12 are operating nor-
mally. No response from unit number 13 onwards.
Response code
Run status
4 bytes
2 bytes
Description
Section 4-5
Related
information
2 bytes

Advertisement

Table of Contents
loading

This manual is also suitable for:

E3x-srt21E3x-cif11

Table of Contents