Always - Omron E3X-DRT21 Operation Manual

Fiber amplifier sensor communication units
Table of Contents

Advertisement

DeviceNet Remote I/O Communications
Remote I/O
Communications
Two-word Mode
(Pin 1 ON, Pin 2
OFF)
Sensor Communications Flag
Bit 15 turns ON when communications are established with the Sensors.
Up to 16 Sensors can be connected in this mode. Two words are allocated to
each Sensor in the IN Area of the master.
Word m
Bit
Contents
00
Unit 1 ON/OFF data
01
Unit 2 ON/OFF data
02
Unit 3 ON/OFF data
03
Unit 4 ON/OFF data
04
Unit 5 ON/OFF data
05
Unit 6 ON/OFF data
06
Unit 7 ON/OFF data
07
Unit 8 ON/OFF data
08
Unit 9 ON/OFF data
09
Unit 10 ON/OFF data
10
Unit 11 ON/OFF data
11
Unit 12 ON/OFF data
12
Unit 13 ON/OFF data
13
Unit 14 ON/OFF data
14
Unit 15 ON/OFF data
15
Unit 16 ON/OFF data
Word m+1
Bit
00
Number of Sensors connected, 2
01
Number of Sensors connected, 2
02
Number of Sensors connected, 2
03
Number of Sensors connected, 2
04
Number of Sensors connected, 2
05
Method for setting number of Sensors
06

Always 0.

07
Always 0.
08
Number of Sensors that can communicate, 2
09
Number of Sensors that can communicate, 2
10
Number of Sensors that can communicate, 2
11
Number of Sensors that can communicate, 2
12
Number of Sensors that can communicate, 2
13
Mobile Console Communications Flag
14
Sensor Communications Error Flag
15
Sensor Communications Flag
Number of Sensors Connected
Bits 00 to 04 give the number of Sensors that are currently registered
between 1 and 10 Hex (1 to 16 decimal).
Contents
0
1
2
3
4
Section 2-5
0
1
2
3
4
23