Operating Procedure For Rs-422 Communication Unit - Omron E3X-DRT21 Operation Manual

Fiber amplifier sensor communication units
Table of Contents

Advertisement

Operating Procedure for RS-422 Communication Unit

4-3
Operating Procedure for RS-422 Communication Unit
Step
Item
1
Mount the Communication Unit to the
DIN Track.
2
Connect the Fiber Amplifier Units to the
Communication Unit.
3
Set the Sensors to RUN mode
4
Connect the RS-422 connector.
5
Set the rotary switches.
6
Set the DIP switch.
7
Turn ON the DC power supply.
8
Check the indicators.
9
Start communica-
tions
72
Mount the Unit to the DIN Track. After mounting the Fiber Amplifier Units
to the DIN Track, connect the Units to each other.
Note: To remove the Units from the DIN Track, first slide the Units apart
to disconnect them, and then remove the Units from the DIN Track.
Connect the Communication Unit to the Fiber Amplifier Units by sliding
the Communication Unit until the clips on the end are aligned and a "click"
sound is heard.
Note: Turn OFF the DC power supply before connecting the Units.
Set the mode switches to RUN mode.
Connect the connector for RS-422 communications.
Note: Be sure to connect terminating resistance to the last Communica-
tion Unit for RS-422.
Upper
switch
Middle
switch
Lower
switch
Pin 1
OFF
OFF
ON
ON
Pin 3
OFF
ON
Disconnect the E3X-MC11 Mobile Console before turning ON the DC
power supply.
PWR
RXD
TXD
U.ERR
SS
CompoWay/F
Sends CompoWay/F messages from the master.
message commu-
nications
Details
Sets the CompoWay/F node number (0 to 31); set in combina-
tion with pin 4 of the DIP switch.
Sets the CompoWay/F communications mode (0 to F).
Sets the number of Sensors for communications (1 to 16). This
switch is enabled only when pin 3 of the DIP switch is OFF.
Note: If pin 3 of the DIP switch is ON, the number of Sensors is
set using a CompoWay/F message.
Pin 2
Baud rate setting
OFF
9,600 bps
ON
19,200 bps
OFF
38,400 bps
ON
57,600 bps
Method for setting number of Sensors connected
Use the rotary switch to register the number of Sensors.
Use CompoWay/F messages to register the number of Sensors.
Communications power supply is ON when the PWR indicator is
lit green.
Receiving serial communications when the RXD indicator is lit
yellow.
Transmitting serial communications when the TXD indicator is lit
yellow.
Operating normally when the U.ERR indicator is not lit (no Unit
error).
Sensors communicating when the SS indicator is lit green.
Section 4-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

E3x-srt21E3x-cif11

Table of Contents