Explicit Message Communications
Read Hysteresis Width
Read Custom Flags
34
Reads the hysteresis width of the Sensor for the unit number specified in the
instance ID. The data is given as a 3-digit hexadecimal value. Bits 14 and 15
are used to display the sensing setting.
Bit
Contents
00 to 11 Hysteresis Width
12
Always 0.
13
Always 0.
14
Sensing Setting:
0: Standard
15
2: Super long-distance
3: Super high-speed
Reads whether the following settings for the Sensor of the unit number speci-
fied in the instance ID can be set or monitored from the sensor key switch.
Bit
Contents
00
Hold Setting:
0: Enable
01
1: Not displayed
2: Disable
02
Flashing Setting:
0: Enable
03
1: Not displayed
2: Disable
04
OFF-delay Timer Setting:
0: Enable
05
1: Not displayed
2: Disable
06
Sensing Setting:
0: Enable
07
1: Not displayed
2: Disable
08
Sensitivity Adjustment:
0: Enable
1: Disable
09
Teaching:
0: Enable
1: Disable
10
Display Contents:
0: Enable
1: Disable
11
Zero Reset:
0: Enable
1: Disable
12
Monitor Focus Range:
0: Enable
13
1: Not displayed
2: Disable
14
Display Orientation:
0: Enable
15
1: Not displayed
2: Disable
Section 2-6