Response
Error name
codes
08FF
Service not supported
09FF
Invalid attribute value
16FF
Object does not exist
15FF
Too much data
13FF
Not enough data
0CFF
Object state conflict
20FF
Invalid parameter
0EFF
Attribute not settable
42
3. An error will occur when performing two-point teaching or two-position
teaching if the command for the second point is sent without sending the
command for the first point/position. Send the command for the first point/
position before sending the command for the second one.
4. The Initialize Sensor Settings command will return the settings for each
Sensor to its default value. The Sensor Reset command interrupts the
power by turning the Sensor power OFF and ON again.
There is an error in the service code.
The specified attribute ID is not supported.
The write data is outside the data range.
• Threshold setting is outside setting range.
• Basic settings are outside setting range.
• Timer is not set according to restrictions.
• Hysteresis width is set outside range.
• Custom Flags are set outside range.
• Special Flags are set outside range.
• Number of Sensors connected is not set between 1 and 16.
• Number of Units monitoring incident light are not set between 1 and 16.
The specified instance ID is not supported.
• Number of Units specified in instance ID is greater than number of Sensors
connected.
Size of data is longer than specified size.
Size of data is shorter than specified size.
Specified command cannot be executed.
• Mobile Console is connected.
• Error has occurred in communications with Sensor.
• Sensor is not set to RUN mode.
• The command for the second point/position of a Two-point Teaching or Two-
position Teaching commands was executed without executing the command for
the first one.
• An unsupported command was sent. (For example, a Read Incident Light Level
command was sent to a Terminal Block Unit.)
The specified operation data is not supported.
A write service code was specified for a read-only attribute ID.