Specifications
1-2-2

General Specifications

6
3. The following Fiber Amplifier Units can be connected to products from spe-
cific lots (or later) only:
E3X-DA6, E3X-DA8, E3X-DAB6, E3X-DAB8, E3X-DAG6, E3X-DAG8,
E3X-DA6TW, and E3X-DA8TW
Even one Unit from a previous lot cannot be connected. The Units that can
be connected must have the following lot numbers or later.
Lot No.
Another method for distinguishing which Units can be connected is by
checking whether the printed information "MADE IN JAPAN" on the front is
underlined or not. This information is underlined for those Units that can be
connected.
The printed information "MADE IN JAPAN" indicates whether connection
is possible, as follows:
• Underlined:
• Not underlined: Cannot be connected to Communication Unit.
Model
Communications
method
Power supply voltage
Internal current con-
sumption (per Com-
munication Unit) (See
note.)
Ambient temperature
Ambient humidity
Storage temperature
Dimensions
Weight (packed state) Approx. 150 g
Note The current supplied to the Sensor is not included in the specification.
Manufactured on June 18, 2001
18
6 01
Year of manufacture expressed as last two
digits of the year.
Month of manufacture. Oct., Nov., and Dec. are
expressed as X, Y, and Z respectively.
Day of manufacture.
• Underlined
Brown :
12 to 24 VDC
Blue : 0 V
Black :
OUTPUT
MADE IN JAPAN
Can be connected to Communication Unit.
E3X-DRT21
DeviceNet
CompoBus/S
11 to 25 VDC
14 to 26.4 VDC
70 mA max.
30 mA max.
–20 to 55•C
Operating and storage: 35% to 85% (with no condensation)
–30 to 70•C
30 ™ 34.6 ™ 71.3 mm (W ™ H ™ D)
Approx. 150 g
Section 1-2
• Not underlined
Brown :
12 to 24 VDC
Blue : 0 V
Black :
OUTPUT
MADE IN JAPAN
E3X-SRT21
E3X-CIF11
RS-422
11.4 to 26.4 VDC
(12 VDC –5% to
24 VDC +10%)
40 mA max.
Approx. 200 g

Advertisement