Operating Procedure for DeviceNet Communication Unit

2-3
Operating Procedure for DeviceNet Communication Unit
Step
Item
1
Mount the Communication Unit to
the DIN Track.
2
Connect the Fiber Amplifier Units
to the Communication Unit.
3
Set the Sensors to RUN mode.
4
Connect the DeviceNet communi-
cations connector.
5
Set the rotary switches.
6
Set the DIP switch.
7
Turn ON the DC power supply (V+,
V– DeviceNet communications
power supply).
8
Check the indicators.
9
Start communications.
20
Mount the Unit to the DIN Track. After mounting the Fiber Amplifier Units to the
DIN Track, connect the Units to each other.
Note: To remove the Units from the DIN Track, first slide the Units apart to dis-
connect them, and then remove the Units from the DIN Track.
Connect the Communication Unit to the Fiber Amplifier Units by sliding the
Communication Unit until the clips on the end are aligned and a "click" sound
is heard.
Set the mode switches to RUN mode.
Connect the DeviceNet Communications Connector.
Note: The DC power supply to the Communication Unit and all Fiber Amplifier
Units connected to it is supplied from the DeviceNet communications power
supply (V+, V–).
Two
Sets the DeviceNet node address (0 to 63).
upper
switches
Lower
Sets the number of Sensors connected to the Unit (1 to 16).
switch
(Enabled when DIP switch pin 3 is OFF only.)
Note 1: When DIP switch pin 3 is ON, set the number of Sensors
connected using the Configurator or explicit messages.
Note 2: Fiber Amplifier Units (E3X-DA6TW, E3X-DA8TW) that are
allocated two unit numbers must be counted as two Units
when counting the number of Sensors.
Pin 1
Pin 2
Operating mode setting
OFF
OFF
Remote I/O communications
one-word mode
ON
OFF
Remote I/O communications
two-word mode
OFF
ON
Remote I/O communications
two-word mode with incident
light level monitoring
Pin 3
Method for setting the number of Sensors.
OFF
Use the rotary switch to register setting.
ON
Use the Configurator or explicit messages to register settings.
Disconnect the E3X-MC11 Mobile Console before turning ON the DC power
supply.
MS
Operating normally when lit green.
NS
Operating normally when lit green
(DeviceNet online and communications connected).
SS
Communicating with Sensors when lit green.
Remote
Enable the scan list in the master and change the PLC to RUN
I/O
mode.
Explicit
Send explicit messages from the master.
mes-
sages
Details
Number of Sensors
connected
13 max.
16 max.
16 max.