Omron E3X-DRT21 Operation Manual page 44

Fiber amplifier sensor communication units
Table of Contents

Advertisement

Explicit Message Communications
Read Basic Settings
Read Timer Settings
This command cannot be used if one or more E39-TM1 Terminal Block Units
is connected.
Reads the basic settings of the Sensor for the unit number specified in the
instance ID. The data contents are as follows:
Bit
Contents
00
Display Contents:
01
0: Digital incident level
1: Digital percentage
2: Analog incident level
02
Display Orientation:
0: Standard
1: Reversed
03
Hold Setting:
0: OFF
04
2: Peak
3: Bottom
05
Flashing Setting:
0: OFF
1: ON
06
Sensing Setting:
0: Standard
07
2: Super long-distance
3: Super high-speed
08
Timer Mode:
1: OFF-delay
09
2: ON-delay
3: One-shot
10
Number of Display Digits:
0: 4 digits
11
1: 3 digits
12
2: 2 digits
3: 1 digit
4: 0 digits
13
Always 0.
14
Teaching during RUN
0: OFF
1: ON
15
Eco Mode
0: OFF
1: ON
Reads the OFF-delay, ON-delay, and one-shot timers of the Sensor for the
unit number specified in the instance ID. The data is given as a 2-byte (4-digit)
hexadecimal value. The value is given in ms.
Section 2-6
33