Explicit Message Communications
Read Basic Settings
Read Timer Settings
This command cannot be used if one or more E39-TM1 Terminal Block Units
is connected.
Reads the basic settings of the Sensor for the unit number specified in the
instance ID. The data contents are as follows:
Bit
Contents
00
Display Contents:
01
0: Digital incident level
1: Digital percentage
2: Analog incident level
02
Display Orientation:
0: Standard
1: Reversed
03
Hold Setting:
0: OFF
04
2: Peak
3: Bottom
05
Flashing Setting:
0: OFF
1: ON
06
Sensing Setting:
0: Standard
07
2: Super long-distance
3: Super high-speed
08
Timer Mode:
1: OFF-delay
09
2: ON-delay
3: One-shot
10
Number of Display Digits:
0: 4 digits
11
1: 3 digits
12
2: 2 digits
3: 1 digit
4: 0 digits
13
Always 0.
14
Teaching during RUN
0: OFF
1: ON
15
Eco Mode
0: OFF
1: ON
Reads the OFF-delay, ON-delay, and one-shot timers of the Sensor for the
unit number specified in the instance ID. The data is given as a 2-byte (4-digit)
hexadecimal value. The value is given in ms.
Section 2-6