E05 Motor Resync; E06 Lc Control; F00 References Menu - Zener MSC-3 Instruction Manual

Speed controllers
Hide thumbs Also See for MSC-3:
Table of Contents

Advertisement

MSC-3 Start Up

E05 Motor Resync

Available Choices:
• Press  once to begin.
• Use the ▲ / ▼ buttons to enable or disable reset by power fail operation.
• Press  to confirm the choice.
When enabled, the MSC-3 will scan for the motor shaft speed. When detected, a smooth transition into
operation begins. The motor resynchronisation function avoids current limit braking.

E06 LC CONTROL

Available Choices:
• Press  once to begin.
• Use the ▲ / ▼ buttons to enable or disable reset by power fail operation.
• Press  to confirm the choice.
This function mobilises internal logic to control an external mains supply contactor. The external
contactor is driven whenever a motor start is required and so must be used in conjunction with > LC
CONTROL relay function. See the Line Contactor Start Control feature for details.

F00 REFERENCES Menu

Items found in this menu allow for speed reference choices for the MSC-3 operating modes remote,
local ESO jog forward and jog reverse. Additionally other reference selections and parametric
configuration are found within this menu. Some reference choices and parameters are related to
connected option cards. If an option card is not fitted, its reference choices will not appear in any lists
and its parameters will not be visible.
84
E05 Motor Resync
>
DISABLED
ENABLED
DISABLED
E06 LC CONTROL
>
DISABLED
ENABLED
DISABLED