Reference Selector

The reference selector is a multiplexor function that uses three digital inputs to select 1 of 8 reference
sources. The High/Low states of the three digital inputs I16 Selector 1, I17 Selector 2 and
I18 Selector 3 make 8 unique combinations. Each combination is assigned a reference source as given
in the table below:
I16 Selector 1
Low
Low
Low
Low
High
High
High
High
The diagram below illustrates this feature:
F06 USER REF 1
F07 USER REF 2
F102 Preset 3
F103 Preset 4
F104 Preset 5
F105 Preset 6
F106 Preset 7
F107 Preset 8
I16 Selector 1
I17 Selector 2
I18 Selector 3
User References
There are 2 customisable inputs to the reference selector. They are F06 USER REF 1 and
F07 USER REF 2. Each of these parameters is itself a single reference selection from the list of available
speed reference sources.
Key configuration parameters are:
• F06 USER REF 1 and F07 USER REF 2
• F100 Preset 1 to F107 Preset 8
• I16 Selector 1 to I18 Selector 3 (input terminal selection)
• > REF SELECT (as a speed reference in REMOTE, LOCAL, ESO, etc)
I17 Selector 2
Low
Low
High
High
Low
Low
High
High
1 of 8
Reference
Selector
IM00120
IM00120
MSC-3 Instruction Manual
I18 Selector 3
Selected Reference
Low
High
Low
High
Low
High
Low
High
Selected Reference
F06 USER REF 1
F07 USER REF 2
F102 Preset 3
F103 Preset 4
F104 Preset 5
F105 Preset 6
F106 Preset 7
F107 Preset 8