E030 ARs ALLOWED
Range: 0...15 attempted restarts
• Press to edit the value.
• Press ▲/ ▼ to make changes to the value.
• Press to accept the new value OR
• Press ESC to abandon the value change.
This number indicates how many times the MSC-3 will attempt to restart after a trip. For the motor to
run after the trip is cleared, the drive must be given a valid run command. Select 0 restarts in order to
deactivate Auto Restart.
E031 AR CLR TIME
Range: 1...1200 seconds
• Press to edit the value.
• Press ▲/ ▼ to make changes to the value.
• Press to accept the new value OR
• Press ESC to abandon the value change.
If the MSC-3 operates for the E031 A/R CLR TIME without any trips, the number of restarts is reset to
the value of E030 A/Rs ALLOWED. Set the E031 A/R CLR TIME to 6 secs for infinite auto restarts
E04 Reset by PF
Available Choices:
• Press once to begin.
• Use the ▲ / ▼ buttons to enable or disable reset by power fail operation.
• Press to confirm the choice.
When enabled trips may be cleared without any extra wiring simply by turning the power off and straight
back on again before the drive powers down completely.
E030 ARs ALLOWED
0
E031 AR CLR TIME
1200 secs
E04 Reset by PF
>
DISABLED
ENABLED
DISABLED
IM00120
IM00120
MSC-3 Instruction Manual
83