Define LF Code
The Define LF Code option controls the action of the printer when it receives a Line Feed code (hex 0A)
from the host computer. If this feature is enabled, each time the printer receives a Line Feed, it inserts an
additional Carriage Return code (hex 0D) into the data stream. This feature can be used in most
installations, but it is required if the host computer does not send Carriage Returns to the printer.
LF = CR + LF. Adds an extra Carriage Return with each Line Feed.
LF = LF. Does not add a Carriage Return with a Line Feed.
Printer Select
Disable. Ignores the ASCII DC1 and DC3 control codes.
Enable. Disables the printer when a DC1 control code is received, and enables the printer when a
DC3 control code is received.
Character Set
This parameter selects a character set for the Epson
emulation when OKI is selected.
20 CPI Condensed
Compressed print characters are narrower than the normal character set. This is helpful for applications
for which you need to print the maximum amount of information on a page.
Enable. Prints about 60 percent of the width of normal characters when compressed print is chosen
by the host computer. For example, a 12 CPI Draft font will compress to 20 CPI.
Disable. Does not compress print widths, even if condensed print is chosen by the host.
NOTE: This parameter is not available for Hanzi GB printers with OKI selected.
Alt. Set 80-9F
Control Code. Interprets data in the range of hex 80 through hex 9F as a control code.
Printable. Prints data in the range of hex 80 through hex 9F.
NOTE: This parameter is not available for Hanzi GB printers with OKI selected.
Currency Sign
RMB Select. The ASCII code hex 24 is printed as a RMB "¥" character in DBCS mode. Default for
GB.
$ Select. The ASCII code hex 24 is printed as a dollar "$" character in DBCS mode.
NOTE: Available for H-Series GB firmware with LQ1600K selected only.
AR3240
Disable. AR3240 emulation does not take effect. Default.
Enable. AR3240 takes effect, SUB (0x1A) is used as another SFCC. The listed commands will take
effect and turn the extending table character on.
NOTE: Available for H-Series GB firmware with LQ1600K selected only.
®
emulation when LQ1600K is selected and for OKI