Autowrap
Defines the printer actions when print data is received past the form width setting.
With LF+CR (factory default). Performs an automatic carriage return and line feed when data is
received past the form width.
With CR. Performs an automatic carriage return (without line feed) when data is received past the
forms width.
Disable . Discards any data past the form width.
Define LF Code
Controls the action of the printer when it receives a Line Feed code (hex 0A) from the host computer. If
this feature is enabled, each time the printer receives a line feed, it inserts an additional carriage return
code (hex 0D) into the data stream. This feature can be used in most installations, but it is required if the
host computer does not send carriage returns to the printer.
LF = CR + LF (factory default). Adds an extra carriage return with each line feed.
LF = LF. Does not add a carriage return with a line feed.
Character Set
This parameter selects a character set for the ANSI emulation. Note that when 0876 OCR-A or 0877
OCR-B is selected as the print language, the Font Attributes Typeface parameter is changed to OCR-A or
OCR-B, respectively. Character sets are shown in detail in the Character Sets Reference Manual.
Printer Select
ON = DC1/OFF = DC3 (factory default). Disables the printer when a DC1 control code is received,
and enables the printer when a DC3 control code is received.
Disable. Ignores the DC1 and DC3 control codes.
ESC c Sequence
Enable (factory default). An ESC c code received from the host resets the printer parameters to the
factory defaults.
Disable. An ESC c code received from the host is ignored.
Reset Cmd CFG Ld
When the printer receives a host data stream reset command (ESC @ or ESC[K) in addition to resetting
printer variables, the selected configuration will be loaded.
Disable (factory default). The active emulation parameters are loaded when the reset command is
executed.
Power-Up Config. The power-up configuration is loaded when the reset command is executed.
Current Config. The currently selected configuration is loaded when the reset command is executed.
Factory Config. The factory installed configuration is loaded when the reset command is executed.
Received CR
Observe (factory default). A CR code received from the host is handled as a carriage return.
Ignore. A CR code received from the host is ignored.